NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Test gauge connections are provided on the
front of the millivolt gas control valve (identi-
fied IN for the inlet and OUT for the manifold
side). See Figures 1 & 2.
This appliance must not be connected to a
chimney or flue serving a separate solid-fuel
appliance.
Burn-in Period
During the first few burns of these appliances
there will be some odor due to the curing of the
high temperature paint and burning off of lubri-
cants used in the manufacturing process.
Depending on your use, the burn-in period may
take a few hours or a few days. Do not turn on
blower during Burn-In period.
IMPORTANT
Keep your house well ventilated
during the curing process. The
odor and haze emitted by the
curing process can be quite
noticeable and may set off a
smoke detector.
O
N
O
F
F
P
I
L
O
T
L
O
H
I
Figure 1
GAS CONTROL
KNOB
CONVERTIBLE
HI/LO REGULATOR
(adjusts flame height
and heat output)
INLET
PRESSURE
TAP
PILOT
ADJUSTMENT
SCREW
WIRING
TERM-
INALS
OUTLET
PRESSURE
TAP
Model EBVI30
Honeywell Millivolt Gas Valve Controls
TP/TH
PIEZO
IGNITER
TH
TP
H
I
L
O
W
TPTH TP TH
P
I
L
O
T
P
I
L
O
T
O
N
it
O
F
F
IN
OUT
Figure 2
MODEL EBVI25
SIT Millivolt Gas Valve Controls
GAS CONTROL
KNOB
INLET
PRESSURE
TAP
OUTLET
PRESSURE
TAP
CONVERTIBLE
HI/LO REGULATOR
(adjusts flame height
and heat output)
PIEZO
IGNITER
GAS CONTROLS
These millivolt appliances are fitted with a burner
Off/On Switch, located on the side surround
panel as shown in Figure 4 on Page 4. Once the
pilot is lit, and valve knob is in the ON position,
the Off/On switch will control the appliance
Off/On operation. To operate, toggle the switch
between its ON and OFF positions.
Variable Flame Height Adjustment
These millivolt appliances are equipped with
variable gas control valves. Flame height may
be adjusted through a range between fixed low
and high settings by rotating the HI/LO knob on
the valve (see Figures 1 & 2) while the appliance
is in operation.
Lighting Millivolt Appliances
To light millivolt appliances refer to the detailed
lighting instructions found on Page 15 (Eng-
lish) and Page 16 (French). Millivolt appliance
lighting instructions may also be found on the
pull-out lighting instruction labels located in the
control compartment (below glass door).
This appliance must be isolated from the
gas supply piping system (by closing its
individual manual shut-off valve) during
any pressure testing of the gas supply
piping system at test pressures equal to
or less than 1/2 psig (3.5 kPa).
This appliance and its individual shut-off
valve must be disconnected from the gas
supply piping system during any pressure
testing of that system at pressures greater
than 1/2 psig (3.5 kPa).
CONTROL COMPARTMENT ACCESS
Pull down hinged door to access control
compartment (see Figure 3).
Control Compartment Access
Pull down hinged door to access control compartment
Pull down lower
louver (hinged)
Side View of Insert
Figure 3
Figure 4
Burner Off/on Switch and Rheostat Location
If optional surround is installed
Burner Off/On
Switch
Rheostat
(blower
speed
control)
Left Front
surround
Panel
Units with Beveled Surround
Units with Flat Surround
Left Front
surround
Panel
Rheostat
(blower
speed
control)
Burner Off/on
Switch