Kuppersbusch USA GKS 324.0 Water Heater User Manual


 
GKS 324.0/GKS 644.0 Installation LP gas 7
Technical data
Table of heat input
GKS 324.0
Total nominal heat input = 11942 Btu/h
Connected load of the appliance = 252 g/h
GKS 644.0
Total nominal heat input = 24908 Btu/h
Connected load of the appliance = 526 g/h
Cross calorific value and pressure
For Service: removal and replacement
[
The power supply and the gas supply should always be turned off during
repairs or connection. To avoid potential safety hazards, make sure all
installation, service and maintenance has been performed according to
guidelines.
Removal:
Press the cooktop out of the worktop from below and remove.
Do not lift the cooktop out of the recess with a screwdriver - You could
damage the frame of the cooktop. Press the cooktop out of the recess from
underneath in order to dismantle.
Replacement:
Insert the rear edge of the
cooktop and carefully lower.
At the same time press in
the clip with both hands.
Press the cooktop down-
wards until it rests com-
pletely on the worktop.
Place the burner cover, the saucepan support(s) and attachment carefully
in the correct position.
Insert plug into the socket.
Burner Propane
Input
Btu/h
Gas rate
g/h
Simmering burner large 3753 79
small 1024 22
Normal burner large 6483 137
small 1297 27
High-speed burner large 8189 173
small 1911 40
Type of gas Caloric value H
s
15 °C pressure
MJ/m
3
Btu/foot
3
inch water
column
Propane 93,1 2500 10
For technical information and/or
replacement parts, please contact the
Küppersbusch Customer Care line
at
1-800-459-0844
For the most efficient assistance,
please have the Model and Serial
numbers for the appliance available.