Kramer Electronics TP-330FW Water Heater User Manual


 
Wiring the TP LINE IN/LINE OUT RJ-45 Connectors
7
7
On both TP-330FW units:
The ON LEDs light green indicating that they are receiving power
and
The CAT 5 LINK LEDs light green indicating that a CAT 5 link has been
established between the units
Notes:
You can connect two FireWire devices simultaneously to a TP-330FW,
however, only one device can be active at a time
There is no need to install the Kramer PT-1FW DV Line Protector on the
STP/UTP as the TP-330FW already contains built-in line protection
You can connect devices with 1394b (FireWire 800) bilingual interfaces at
speeds of up to 400Mbps. The FireWire cable used must have a bilingual
connector on one side and a 1394a 6-pin connector on the other side
6 Wiring the TP LINE IN/LINE OUT RJ-45 Connectors
Table 2
and Figure 3 define the TP RJ-45 wiring that is different to the standard
EIA/TIA 568B wiring. When using STP cable, connect/solder the cable shield to
the RJ-45 connector shield.
Table 2: Twisted Pair Cable Wiring
PIN Wire Color PIN
1 Green/White 7
2 Green 8
3 Orange/White 3
4 Blue 4
5 Blue/White 5
6 Orange 6
7 Brown/White 1
8 Brown 2
36
7
812
5
4
1
4
5 7
8632
Figure 3: UTP Connector