Kohler K-3394 Plumbing Product User Manual


 
3Kohler Co., Kohler, WI
113362-2-EA (9532)
ROUGH-IN PLUMBING
Turn off the main water supply.
Install or relocate the supplies and outlets as necessary
to conform to roughing-in dimensions. See Fig. #3 . For
supply stop location, See Fig. #4 .
CAUTION: Risk of trap seal loss in
back-to-back installations. See Fig. #2 . To
prevent possible trap seal loss, the back-to-back
Pressure Lite toilet should be connected to a vertical
stack using one of the following three fittings:
S Double fixture fitting
S Double combination wye and 1/8 bends
S Double wye and 1/8 bends
Fig. #2
Double
Fixture
Fitting
Double
Combination
Wye and 1/8
Bends
Double Wye
and 1/8
Bends
ROUGHING-IN DIMENSIONS
Fig. #3
116
3/4”
30-1/2”
3-1/16”
12”
2-3/4”
14-3/4”
19-3/8”
2-5/8”
7-3/4”
10”
16-1/4”
4-5/8”
C
L OF OUTLET
3/8” I.P.S. SUPPLY
FRONT OF BOWL
19-1/4”
INSTALL SUPPLY STOP
For supply installation, refer to the instructions packed
with the supply stop.
Locate the supply stop so it is 2-5/8” above the floor line,
and 7-3/4” to the left of the centerline of the closet flange.
Fig. #4
Supply Stop
2-5/8”
7-3/4”
12”