Service the Diaphragm
NOTE: Disassemble the faucet following the steps in the
Disassemble the Faucet section.
Disconnect the wire connectors and set the faucet body aside.
Using a Phillips screwdriver, remove the four screws.
Check the O-ring for wear. Replace if worn.
Remove the diaphragm from the back of the faceplate by gently
prying it away with your fingers.
Rinse off any debris.
Position the replacement diaphragm and snap it into place.
Reinstall the faceplate and secure with the four screws.
Proceed to the Reassemble the Faucet section.
Service the Plug
NOTE: Disassemble the faucet following the steps in the
Disassemble the Faucet section.
Disconnect the wire connectors and set the faucet body aside.
Use a hex wrench to remove the plug.
Install the replacement plug assembly and securely wrench
tighten.
Proceed to the Reassemble the Faucet section.
Screw
O-Ring
Plug
Diaphragm
Assembly
Faceplate