KitchenAid KBZU242TSS Burner User Manual


 
6
Built-In Outdoor Side Burner Enclosure
The enclosure for the built-in outdoor side burner is to be a
minimum of 11" (28.0 cm) high x 23" (58.4 cm) deep x
14" (35.6 cm) wide for front to back model and 11" (28.0 cm)
high x 17" (43.2 cm) deep x 25" (63.5 cm) wide for side by side
model.
Cabinet Dimensions
Enclosure and clearance dimensions that are shown must be
used. Given dimensions provide required clearances.
Counter or support surfaces must be level.
The installation of this side burner must conform with local codes
or, in the absence of local codes, with either the National Fuel
Gas Code, ANSI Z223.1/NPFA 54, Natural Gas and Propane
Installation Code, CSA B149.1, or Propane Storage and Handling
Code, B149.2.
Copies of the standards listed may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
NOTE: The outdoor side burner drops into the enclosure opening
and is supported by its side flanges. No bottom support is
needed.
Built-in Outdoor Side Burner Enclosure Ventilation for
LP Gas:
An enclosure for an LP gas fuel tank is to be ventilated by
openings at both the top and lower levels of the enclosure.
If converting to LP gas these vents are to be in the enclosure:
An enclosure for use with an LP gas fuel tank for built-in
installation is to have at least one ventilation opening on an
exposed exterior side located within 5" (12.7 cm) of the top and is
to be a minimum of 20 in.
2
(129.0 cm
2
). One ventilation opening
within 1" (2.5 cm) of the bottom of the enclosure and the bottom
opening is to be a minimum of 10 in.
2
(64.5 cm
2
). All vent
openings are to be unobstructed. Every opening is to be a
minimum of ¹⁄₈" (0.32 cm) wide.
Electrical Requirements
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
Check with a qualified electrician if you are not sure whether the
side burner is properly grounded.
A 120-volt, 60-Hz, AC-only, 15-amp, fused electrical supply is
required.
It is recommended that a separate circuit servicing only this side
burner be provided.
The model/serial number rating plate is located on the right-hand
side panel. See the following illustration.
A.12" (30.5 cm) minimum to side
burner or any accessory
B.13¹⁄₂" (34.3 cm) on front to back
models, 24¹⁄₂" (62.2 cm) on side by
side models
C.22⁵⁄₈" (57.5 cm) on front to back
models, 16⁷⁄₈" (42.9 cm) on side by
side models
D.2¹⁄₄" (5.7 cm)
E.6¹⁄₄" (15.7 cm)
F. Gas line location at rear of
side burner
G.10³⁄₄" (27.3 cm)
H.35¹⁄₂" (90.2 cm)
A
B
C
D
E
F
G
H
A.Model/serial number plate
10 in.
2
(64.5 cm
2
) min.
ventilation both sides
5" (12.7 cm) max.
1" (2.5 cm) max.
20 in.
2
(129.0 cm
2
) min.
ventilation both sides
5" (12.7 cm) max.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
A