Kidde KN-COEG-3 (900-01 13) Carbon Monoxide Alarm User Manual


 
7. Maintenance
Move the CO and Gas alarm to a remote location, to prevent possible
damage or contamination of the sensor, prior to performing any of the
following:
• Staining or stripping floors or furniture, painting or wall-papering
• Using aerosols or adhesives
WARNING: Reinstall the CO and Gas alarm as soon as possible to assure
continuous protection.
The following is a list of substances that at high levels can damage the
sensor or cause temporary readings that are not CO readings:
• Ethylene, ethanol, alcohol, iso-propanol, benzene, toluene, ethyl
acetate, hydrogen, hydrogen sulfide and sulfur dioxide.
• Also most aerosol sprays, alcohol based products, paint, thinner, sol-
vent, adhesive, hair spray, after shave, perfume, auto exhaust (cold
start) and some cleaning agents.
2509-7214-01(820-1557B ):_ 2010.2.1 9:27 AM Page 21