Kidde KN-COSM-IBCA Carbon Monoxide Alarm User Manual


 
• Voice Message System that alerts user to the
following additional conditions:
• System announces, "Hush
®
mode on! Mode Hush
®
activé!" when the unit is first put into Hush
®
Mode.
• System announces, "Hush
®
mode cancelled! Mode
Hush
®
annulé!" when unit resumes normal
operation after Hush
®
Mode has been cancelled.
• System announces, "Caution! Attention!" when the
unit has detected CO concentrations of 100 ppm or
higher.
• One "chirp" every 30 seconds indicates that the
alarm is malfunctioning. If this occurs call the
Consumer Hotline at 1-800-880-6788.
• Peak Level Memory Feature which alerts user when
the unit has detected CO concentrations of 100 ppm
or greater (see Page 17).
• Alarm Memory Feature that gives visual indication
when the alarm has sensed a hazardous condition.
• Green and red LED lights that indicate normal
operation and alarm status (see Page 18 for details).
• Tamper Resist Feature that deters children and others
from removing the alarm (see Page 19).
• For initial installation, model KN-COSM-IBCA
includes a pre-installed 9 V battery, and a battery
pull tab that allows for easy connection. Simply pull
the tab out, and the battery backup is connected!
• Model KN-COSM-IBCA is equipped with a battery
reminder tab that prohibits installation when a
battery is not present.
• Smoke alarm takes precedence when both smoke
and carbon monoxide are present.
• Seven (7) years after initial power up, this unit will
"chirp" every 30 seconds to indicate that it is time to
replace the alarm.
• Permanent, independent smoke and carbon
monoxide sensors (ionization and electrochemical).
• Powered by 120 V AC (60 Hz, 25 mA max) Quick-
Connect wire harness. Model KN-COSM-IBCA is
also equipped with a 9 V battery backup.
• Interconnectable to other alarms and safety
accessories (see Page 16 for details).
• Loud 85 decibel alarm.