This smoke alarm uses a 9V carbon zinc battery (alkaline and lithium batteries
may also be used). A fresh battery should last for one year under normal operat-
ing conditions.
This alarm has a low/missing battery monitor circuit which will cause the alarm
to “chirp” approximately every 30-40 seconds for a minimum of seven (7) days
when the battery gets low.Replace the battery when this condition occurs.
NOTE: Low/missing battery monitor circuit WILL cause the unit to chirp while
replacing the battery. This function will cease once the new battery has been
installed. To avoid this “chirp” the unit can be removed from the base and dis-
connected from the AC power when replacing the battery, but it is not necessary.
USE ONLY THE FOLLOWING 9 VOLT BATTERIES FOR SMOKE ALARM
BATTERY REPLACEMENT.
Carbon-zinc type EVEREADY 1222; GOLD PEAK 1604P OR 1604S
Alkaline type ENERGIZER 522; DURACELL MN1604 OR MX1604; GOLD
PEAK 1604A PANASONIC 6AM6, 6AM-6, 6AM-6PI,
6AM6X, AND 6LR61 (GA)
Lithium type ULTRALIFE U9VL-J
These smoke alarms can be purchased at your local retailer.
NOTE: WEEKLY TESTING IS REQUIRED!
WARNING! BE SURE TO FOLLOW BATTERY INSTALLATION INSTRUCTIONS
PRINTED ON THE BACK OF THE ALARM AND USE ONLY THE BATTERIES
SPECIFIED. USE OF DIFFERENT BATTERIES MAY HAVE A DETRIMENTAL
EFFECT ON THE SMOKE ALARM.
WARNING: THIS ALARM WILL “CHIRP” IF ABNORMAL OPERATION OF THE
SMOKE-SENSING CHAMBER IS DETECTED. THIS CHIRP WILL OCCUR
APPROXIMATELY 20 SECONDS AFTER THE RED LED FLASH. REPLACE THE
ALARM IF THIS CONDITION OCCURS.
PRESS OPEN INSERT
1260-7205-01(820-0394G-EN)_v1.qxd:_ 2011.5.16 10:15 AM Page 12