Kidde 0916E Smoke Alarm User Manual


 
1394 South Third Street, Mebane NC 27302
1-800-880-6788 • www.kiddeus.com
Architectural and Engineering
Specifications
The smoke alarm shall be Kidde Unit Number 0916E (part
number 0916E) or approved equal. It shall be powered by a
9V battery. The unit shall incorporate an ionization smoke
sensor with nominal sensitivity of 1.26%/ft. The tempera-
ture operating range shall be between 40˚F and 100˚F (4˚C
and 38˚C) and the humidity operating range shall be 5% -
95% relative humidity.
The alarm can be installed on the surface of any wall or
ceiling following the UL/NFPA/Manufacturer’s recommended
placement guidelines. The unit shall provide optional tam-
per resistance that deters removal of the unit from the wall
or ceiling.
The alarm shall include a test button that will electroni-
cally simulate the presence of smoke and cause the unit to
go into alarm. This sequence tests the unit’s electronics,
battery and horn to ensure proper operation.
The unit shall include a piezoelectric horn that is rated
at 85 decibels at 10 feet. In a smoke incident, the horn will
sound in the repetitive manner – three (3) beeps, a pause,
three (3) beeps, a pause.
The unit shall include the Hush
®
feature that silences
the unit. By pressing the Hush
®
button, it will desensitize
the unit for approximately 7 minutes if a nuisance condition
occurs. The alarm will chirp every 30-40 seconds during
this time and will automatically reset after approximately 7
minutes and sound the alarm if particles of combustion are
still present. The Hush
®
feature shall be overridden and the
unit will alarm if the smoke is too dense.
The unit shall also include a low battery warning utiliz-
ing a brief alarm chirp every 30-40 seconds for a minimum
of seven (7) days.
The alarm will utilize a red LED that shall flash once every
30-40 seconds to indicate the alarm is receiving power.
Battery Operated Smoke Alarm
with Hush
®
Unit Number 0916E
Technical Specifications
Unit Number: 0916E
UPC Number: 0-25417-00916-3
Power Source: 9V Battery (included)
Sensor: Ionization
Audio Alarm: 85dB at 10ft
Temperature Range: 40˚F (4.4˚C) to 100˚F (37.8˚C)
Humidity Range: 5%-95% relative humidity (RH)
Size: 5” in diameter x 1.5” depth
Weight: 1lb
Interconnects: No
LED: Red, normal operation
Warranty: 5 year limited
Ordering Information
Part Dimensions Case/ Layers/ Skid
Number UPC I 2 of 5 Pack Quantity Battery Type (w x d x h inches) Weight Skid Skid Weight
0916E** N/A N/A Individual N/A 5.75 x 2 x 6 1lb N/A N/A N/A
0916E 0-25417- 200 25417 Master Pack 9V Battery 5.25 x 10.50 x 10.75 12.20lbs 128 8 1558lbs
00916-3 00196 7 (12 units)
0916LLE 0-25417- 200 25417 Master Pack Long Life Lithium 5.25 x 10.50 x 10.75 12.10lbs 128 8 1550lbs
91612-6 91612 0 (12 units) 9V Battery
The unit shall at a minimum meet the requirements of
UL217, NFPA72, (chapter 11 2002 edition) The State of
California Fire Marshall, NFPA101 (One and two family
dwellings) Federal Housing Authority (FHA), Housing and
Urban Development (HUD). It shall also include a 5-year
manufacturer’s limited warranty.
**Not for sale by individual unit
MASTER PACK
12
1
UNIT
5" 1.5"
Distributed by: