Kenmore 625.34857 Water System User Manual


 
SERVICE TECH INFORMATION
SECTION 5
23
5A. TROUBLESHOOTING
MANUAL ADVANCE REGENERATION CHECK
This check verifies proper operation of the valve
motor, brine tank fill, brine draw, regeneration flow
rates, and other controller functions. Always make
the initial checks, and the manual initiated
diagnostics.
NOTES: The face plate display must show a steady
time (not flashing). If an Error code shows, first press
the SELECT button to enter the diagnostic display.
1. Press the ON/OFFĆHOLD button and hold in for
3 seconds. *RECHARGE and Fill begin to flash as
the softener enters the fill cycle of regeneration.
When Fill is on steady, remove the brinewell
cover and, using a flashlight, observe fill water
entering the tank.
*
NOTE: If the CLEAN feature is set to ON, a cleaning
backwash (CLEAN and Bkwsh or Rinse flashes in the
display, along with the minutes of the clean cycle
remaining), precedes the recharge.
a. If water does not enter the tank, look for an obĆ
structed nozzle, venturi, fill flow plug, brine tubĆ
ing, or brine valve riser pipe.
CYCLE FLOW RATES (GALLONS PER MIN.)
FILL (flow to salt storage tank) 0.3 (1.1 liters)
BRINING .19 (.7 liters)
BRINE RINSE
(flow to drain)
.12 (.45 liters)
BACKWASH
(fl
ow
t
o
d
ra
i
n
)
2.0 (7.6 liters)
FAST RINSE 2.0 (7.6 liters)
2. After observing fill, press the ON/OFFĆHOLD
button to move the softener into brining. A slow
flow of water to the drain will begin. Verify brine
draw from the brine tank by shining a flashlight
into the brinewell and observing a noticeable
drop in the liquid level.
NOTE: Be sure a salt bridge is not preventing water
with salt contact.
a. If the softener does not draw brine
nozzle and/or venturi dirty or defective.
nozzle and venturi not seated properly on
gasket.
restricted drain (check drain fitting and
hose).
defective nozzle and venturi seal.
other inner valve defect (rotor seal, rotor &
disc, wave washer, etc.).
NOTE: If water system pressure is low, an elevated
drain hose may cause back pressure, stopping brine
draw.
3. Again press ON/OFFĆHOLD to move the softenĆ
er into backwash. Look for a fast flow of water
from the drain hose.
a. An obstructed flow indicates a plugged top disĆ
tributor, backwash flow plug, or drain hose.
4. Press ON/OFFĆHOLD to move the softener into
fast rinse. Again look for a fast drain flow. Allow
the softener to rinse for a few minutes to flush out
any brine that may remain in the resin tank from
the brining cycle test.
5. To return the softener to service, press ON/OFFĆ
HOLD.