Kenmore 251.90701 Dehumidifier User Manual


 
Error
Code
E0 Temperature
Sensor
E1 Defrost
Sensor
E2 Humidity
Sensor
E3 Pump Drain
Error Type Possible Causes Corrective Actions
1. Sudden change
in the
surrounding
temperature.
i2. Faulty sensor.
1. Improper
bucket
installation.
2. Blockage to
drain hose
system.
3. Back flow of
water through
pump drain
hose.
4. Improper pump
drain hose
installation.
5. Faulty drain
pump.
1. Unplug the dehumidifier.
2. Check the surrounding area for possible
reasons for sudden temperature changes.
3. Wait 30 minutes before plugging the
dehumidifier back in and resuming normal
operation.
4. If the "Error" is still indicated, please
contact your nearest service center.
1. Unplug the dehumidifier.
2. Remove the bucket.
3. Check to make sure that there is nothing
blocking the connection at the base of the
pump or the bucket.
4. Reinstall the bucket, taking care that it is
installed properly.
5. Check to make sure that the pump drain
hose is not crimped or blocked.
6. Check to make sure that the pump drain
hose is not both under water and sitting at
a height above the dehumidifier - this can
cause a "back flow" of water from the hose
to the dehumidifier.
7. Remove and reinstall the pump drain hose,
taking care that the pump drain hose is
installed properly.
8. Plug the dehumidifier in and restart
9. If the "E3" error is still indicated, please
contact your nearest service center.
Classification Spec Remark
Model 251.90701
Power Supply AC 115V/60(Hz)
Moisture Removal 70 Pint(33.11iters) 24-Hour Period
Control Type Electronic
Refrigerant R410A/11.29 oz. 320g
Humidity Humidity Setting: 35%-70% 5% Increments
Display Display Range: 20%-90% 1% Increments. Current Humidity.
Temperature Display Range: Lo, 36-99°F, Hi F Increments. Current Temp.
Display Display Range: Lo, 2-37°C, Hi C Increments. Current Temp.
Timed Shut-off Setting Range: 1Hr-12Hr 1 Hour Increments
Fan Motor Speed 3 Speeds Auto/High/Low
Dimensions 15.74x25.59x13.6 in 400x650x346mm
Net Weight 49 lbs 22.3Kg
Operating Temp. 36°F-99°F
Drain Pump 12V DC
Pump Drain Hose .25 in x 18 ft 6.35x5,486mm
The remote monitoring station is a receiver
with areceiving range of only 330 feet in
open air with no obstructions. Actual receiving
range will vary depending on what is in
the path of the signal transmitted from the
dehumidifier unit. Each obstruction (roof,
walls, floors, ceilings, thick trees, etc.) will
effectively cut signal range in half.
Example: The wireless remote monitor with
a 330-foot range is mounted on an interior
walt or placed on a countertop so the signal
from the dehumidifier has to pass through one
basement wall, across the 10-foot width of the
room through the room's other watt and then
through the floor to the room upstairs where
the receiver is located. The first wall
will reduce the range to 165 feet, and the
second walt will reduce the range to 87 feet.
Factoring inthe 10-foot room, this leaves
a maximum of 77 feet of remaining signal
range. Passing up through the floor has now
reduced the effective range to 38 feet.
Typically this allowance is enough for most
flame-constructed homes; however certain
materials can reduce range even further.
Metal siding, stucco, and some types of
glass can reduce signal range by as much
as 75% compared to the 50% reduction
typical d most obstructions. Itis possible
to receive a signal through these materials;
however maximum range will be much less,
due to their tendency to absorb or reflect
a much larger portion of the dehumidifier's
signal.
NOTE: You may have to move the monitor
closer to the main unit if it is not receiving a
proper signal following set-up procedures.
Setup Guide
Insert the batteries inthe monitor. After
the batteries are inserted, the Monitoring
Station will start receiving signal data from
the dehumidifier: temperature, humidity, etc.
should be displayed on the monitor's screen.
Ifthis doesn't happen after 2 minutes, check
the dehumidifier to make sure it is operating
properly. Remove the batteries from the
monitor, wait a minute, then replace.