Installation Instructions (cont'd)
2. The convertible element is located behind the lower access
panel of the water heater, Remove the two screws securing
the access panel, and remove panel,
5, Remove the screws from terminal 2 of the element, and move
the looped end of the wire aside.
3, Remove the insulation block to expose the opening,_
6, The buss bar is labeled 5500 W. Place the buss bar over termi-
nals 2 and 3 with the 5500 W visible. Install the extra screw
provided into terminal 3,
S5OOW
4o Lower Element: Lift out the tab as shown to unclip the
terminal cover from the thermostat, The terminal cover can
now be removed from the thermostat
TERMINAL COVER pLASTIC TABS ON
CUPPED TO THER- /BOTH SIDF_ OF
H OSTAT AT THIS TERMINAL COVER
POINT HOLD IT tN
PLACE_
LOWER THERHO_TAT
JACKET
7, The wire removed from terminal 2 has a looped end, It must
remain looped and now be placed (as shown) on top of the
buss bar, over the opening of terminal 2, and secured using
the remaining screw°
8. Tighten terminals 2 and 3 to ensure proper electrical
connection,