The appliance and its individual shut-off valve should be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of

the gas supply piping system by closing its individual manual
shut-off valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than 1/2 pound

Connecting the gas piping to the gas control valve of the water
heater can be accomplished by either of the two methods shown
in Figures 19 and 20.
SedimentTraps
Contaminants in the gas lines may cause improper operation

Before attaching the gas line be sure that all gas pipe is clean
on the inside. To trap any dirt or foreign material in the gas

be incorporated in the piping. The drip leg must be readily
accessible. Install in accordance with the Gas Piping section.

ANSI Z223.1/NFPA 54.
A sediment trap should be installed as close to the inlet of the
water heater as practical at the time of water heater installation.

nipple in the bottom outlet or other device recognized as an


in Figures 19 and 20.
FIGURE 19. GAS PIPING WITH FLEXIBLE CONNECTOR.
FIGURE 20. GAS PIPING WITH ALL
BLACK IRON PIPE TO GAS CONTROL.