Kenmore 153 Water Heater User Manual


 
Mineral Buildup or Sediment IVlayAccumalate
. This causes the water heater to become
much heavier than normal.
® Ifspilled, could cause staining.
Mineral buildup or sediment may have accumulated in the old
water heater. This causes the water heater to be much heavier
than normal and this residue, if spilled out, could cause staining.
Facts to Consider About the Location
You should carefully choose an indoor location for the new
water heater, because the placement is a very important
consideration for the safety of the occupants in the building
and for the most economical use of the appliance. This water
heater is not intended for outdoor installation.
Whether replacing an old water heater or putting the water
heater in a new location, the following critical points must be
observed.
The location selected should be indoors as close to and as
centralized with the water piping system as possible. This
water heater, as well as all water heaters, will eventually
leak. Do not install without adequate drainage provisions
so water flow will not cause damage.
Property Damage Hazard
* All water heaters eventually leak
Do not install without adequate drainage.
Sensors mounted in the drain pan that turn offthe water supply
to the entire home when water is detected in the drain pan.
Water supply shut-off devices that activate based on the water
pressure differential between the cold water and hot water
pipes connected to the water heater.
Installations in Residential Garages
. Water heater must be located in a
protective area.
INSTALLATION IN RESIDENTIAL GARAGES: The water heater
must be located and/or protected so it is not subject to physical
damage by a moving vehicle.
The location selection must provide adequate clearances
for servicing and proper operation of the water heater.
Insulation Blankets
Insulation blankets are available to the general public for
external use on electric water heaters but are not necessary
with this product. The purpose of an insulation blanket is to
reduce the standby heat loss encountered with storage tank
heaters. Your water heater meets or exceeds the National
Appliance Energy Conversation Act standards with respect to
insulation and standby loss requirements, making an insulation
blanket unnecessary.
Should you choose to apply an insulation blanket to this heater,
you should follow these instructions below. Failure to follow
these instructions can result in fire, serious personal injury, or
death.
Do not cover the temperature and pressure relief (T & P)
valve with an insulation blanket.
WATER HEATERS EVENTUALLY LEAK: Installation of the water
heater must be accomplished in such a manner that if the tank
or any connections should leak, the flow of water will not cause
damage to the structure. When such locations cannot be
avoided, a suitable drain pan should be installed under the
water heater. Drain pans are available at your local Sears stores.
Such drain pans must be piped to an adequate drain.
Water heater life depends upon water quality, water pressure
and the environment in which the water heater is installed.
Water heaters are sometimes installed in locations where
leakage may result in property damage, even with the use of a
drain pan piped to a drain. However, unanticipated damage
can be reduced or prevented by a leak detector or water shut-
off device used in conjunction with a piped drain pan. These
devices are available from some plumbing supply wholesalers
and retailers, and detect and react to leakage in various ways:
Sensors mounted in the drain pan that trigger an alarm or
turn off the incoming water to the water heater when leakage
is detected.
Do not cover the instruction manual. Keep it on the side of
the water heater or nearby for future reference.
Do obtain new warning and instruction labels for placement
on the blanket directly over the existing labels.
Facts to Consider About the
Convertible Lower Element
The Upper Element (if a double element model) is a
conventional 3800 watt element which only operates at its rated
wattage on 240 volts. (See rating plate on the water heater).
The Lower Element of the water heater can be converted from
operation at 3800 watts to 5500 watts on a 240 volt system.
Read and follow water heater warnings and instructions. If
after reading these instructions in this manual, you do not
understand any portion, call Sears Service Center.