A SERVICE OF

logo

Operating Instructions NT 361 Eco M A / NT 611 Eco M A English
23
Clean electrodes
! Unlock and remove the suction
head
! Clean electrodes
! Replace the suction head and
lock it in place
Fault instructions
If a fault occurs (e.g. a torn filter),
the device must be switched off
immediately.
The fault must be remedied before
restarting.
The suction turbine does not
run
! Check the cable, plug, fuse and
socket.
! Switch on the machine.
The suction turbine switches off
! Empty the container.
The suction turbine does not
restart following emptying of
the container
! Switch the appliance off and
wait for 5 s, switch it on again
after 5 s.
! Clean the electrodes as well as
the space between them.
The suction power decreases
Remove the parts clogging up
the suction nozzle, the suction
tube, the Power Filter Clean
handle, the suction hose or the
flat pleat filter.
! Change the paper filter bag.
! Actuate the filter
cleaner: Power Filter Clean
several times at the handle.
! Engage the filter cover
properly.
! Replace the flat pleat filter.
Dust ejects when sucking
! Check the proper mounting
position of the flat pleat filter.
! Replace the flat pleat filter.
Automatic cut-out (wet suction)
defective
! Clean the electrodes as well as
the space between them.
! Constantly check fill level when
vacuuming electrically non-
conductive liquids.
Power Filter Clean switches
regularly
! Detach blocked suction nozzle
or end of hose.
! Stop continuous vacuuming
from liquid-containing container
or switch off - Power Filter
Clean – function (see chapter
on wet vacuuming).
! Remove the parts clogging up
the suction nozzle, the suction
tube, the Power Filter Clean
handle, the suction hose or the
flat pleat filter.
! Replace the flat pleat filter.