Karcher 600 MP Water System User Manual


 
WTC 600 LP / MP
7
Maintenance and Care
Version 06/05
After a while the indication moves back to the
current time.
3.2.3 Bleeding the Metering Pump
The metering pump must be bled when the pump
has drawn in air (e. g., because the metering con-
tainer is completely empty).
The system stops; the “Motor/hard water“ mal-
function indication is shown in the display.
Fill the empty metering container and mix the
chemicals according to Section 3.2.6.
Unscrew the bleeding screw (34) by one turn.
Press the MANUAL pushbutton (33) until the
medium flows without bubbles through the
bleeding line (35) back into the container.
Screw in the bleeding screw again.
On the control panel, acknowledge the mal-
function indication with the RETURN key but-
ton (36); the system starts.
3.2.4 Replacing the Fine Filter
Check the pressure difference at manometers (15)
and (16). Replace the filter insert when over 0.8 bar:
Switch off the equipment at the main switch (20).
Stop the untreated water supply.
Place a bucket under the untreated water drain
cock (37) and open the cock.
Wait until no more water emerges out of the
cock, then shut the cock again.
Attach the filter wrench (41) to the filter bowl
(40) and screw off the filter bowl.
Remove the filter insert (38) from the filter bowl
and replace with a new one.
i
This malfunction indication is shown in-
dependent of which metering container
is empty.
31
32
34
33
35
i
The filter bowl is still filled with water.
ESC
production / production
produccion / produzione
fault / default
error / guasto
disinfection / nettoyage
desinfeccion / disinfezione
reject / rejet
evacuation / evacuatione
regeneration / regeneration
regeneracion / rigenerazione
tank full / stockage plein
deposito lleno / serbatoto pieno
RO 1000
36
37
41
40
39
38
16
15