Johnson Controls 4000 Humidifier User Manual


 
Humidifier Specifications
Humidifier
Type
Sizing
Sq. Ft. Area
(air changes/hr)
A. Unit Size
(inches)
B. Plenum
Opening
(inches)
Bypass
Connection
Size
Water Feed
Rate
Electrical
Data
UL
Approved
Components
Included
8000 Series
Canister
Steam
Humidifier
120V operation:
750loose(2),1,500average
(1),3,000tight(1/2)
208V operation:
1,350loose(2),2,650average
(1),5,350tight(1/2)
240V operation:
1,500loose(2),3,050average
(1),6,100tight(1/2)
A. 10-1/8Wx
20-7/8Hx
7-1/8D
B. N/A–Unit
canberemote
mounted.
N/A–
Dispersion
tubemounts
through
1-1/4”hole
insupplyor
returnduct.
N/A–Total
waterusage
isoutputplus
approximately
20%fordrain
cycles.
120V-60Hz:
11.5AMP,
1.4kW
208V-60Hz:
11.5AMP,
2.4kW
240V-60Hz:
11.5AMP,
2.8kW
UL
Approval
certified
byETL
ManualHumidistat,
DispersionTube,
SteamHose,Drain
Hose,HoseClamps,
BlowerActivation
Relay,Installation/
Operation&
MaintenanceManual,
OwnersManual
7000 Series
Power
Humidifier
1,050loosehouse(2)
2,100averagehouse(1)
4,200tighthouse(1/2)
A. 15-29/32Wx
18Hx
10-11/32D
B. 14-3/4Wx
14-5/16H
N/A 6gph
120V-60Hz
0.8AMP
Yes
ManualHumidistat
SaddleValve,
InstallationTemplate,
Owner’sManual
6000 Series
Bypass
Humidifiers
1,000loosehouse(2)
2,000averagehouse(1)
4,000tighthouse(1/2)
A. 15-3/8Wx
15-3/4Hx
10-1/4D
6” dia. round
opening
for bypass
connection
B. 10Wx
12-3/4H
6” 3gph
24V-60Hz
0.5AMP
Yes
ManualHumidistat
SaddleValve,
InstallationTemplate,
Owner’sManual,
24-voltTransformer
4000 Series
Water Saver
Bypass
Humidifiers
1,000loosehouse(2)
2,000averagehouse(1)
4,000tighthouse(1/2)
A. 15-3/8Wx
15-3/4Hx
10-1/4D
6” dia. round
opening
for bypass
connection
B. 10Wx
12-3/4H
6” 3gph
24V-60Hz
0.5AMP
No
ManualHumidistat
SaddleValve,
InstallationTemplate,
Owner’sManual,
24-voltTransformer
5000 Series
Bypass
Humidifiers
750loosehouse(2)
1,500averagehouse(1)
3,000tighthouse(1/2)
A. 15-5/8Wx
13Hx
10-1/4D
6” dia. round
opening
for bypass
connection
B. 9-1/2Wx
9-1/2H
6” 3gph
24V-60Hz
0.5AMP
Yes
ManualHumidistat
SaddleValve,
InstallationTemplate,
Owner’sManual,
24-voltTransformer
Series 8000, 7000, 6000, 5000, 4000 humidifier performance based on:
a. 20°F and 70% R.H. Outside Air
b. 0°F and 35% R.H. Room Air
c. Internal Moisture Gain of 1 lb/hr
d. 70% Blower Operation
e. 8 Ft. Ceiling Height
Johnson Controls
Unitary Products
5005YorkDrive,Norman,OK73069
665513-UTG-B-1211
JohnsonControls,UnitaryProductsreservesthe
righttochangespecificationswithoutnotice.