IRiS • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
02/29/2008 4:57:46 PM
Specifications and Dimensions subject to change without notice.
ADI071555
P40832ICAT E4LWW
2’ from wall
(distance from xture along wall)
2’ from wall
(spacing between xtures)
3’ from wall
(spacing between xtures)
DD
n
1' 2' 3'
n ––––– 2’––––– n n ––––– 3’––––– n n ––––– 3’––––– n n ––––– 4’––––– n
1 40 16 4 1 49 34 49 42 17 42 13 9 13 11 5 11
2 41 24 8 3 60 55 60 47 30 47 26 20 26 23 13 23
3 25 18 9 4 45 45 45 32 28 32 27 24 27 22 16 22
4 14 12 7 4 32 32 32 22 21 22 22 22 22 18 16 18
5 8 7 5 3 22 22 22 15 15 15 18 18 18 14 13 14
6 5 4 3 2 15 16 15 11 11 11 14 14 14 11 11 11
7 3 3 2 2 11 11 11 8 8 8 11 11 11 8 9 8
8 2 2 2 1 8 9 8 6 6 6 9 9 9 7 7 7
9 2 1 1 1 6 7 6 5 5 5 7 7 7 5 5 5
10 1 1 1 1 5 5 5 4 4 4 6 6 6 4 5 4
Efficiency = 38.6%
Test No. 254P239
Platform = P406TAT
Element = E4LWWH
Lumens = 2400
Lamp = CF32TTT/E/841
Photometric Results
Single Unit Footcandles Multiple Unit Footcandles
Zone Lumens
%
Lamp
%
Luminaire
0- 30 385 16 41.5
0- 40 574 23.9 61.9
0- 60 837 34.9 90.3
0- 90 927 38.6 100
90-180 0 0 0
0-180 927 38.6 100
Zonal Lumens Summary
CD
Wall
Vertical
Angle
0
4
75
198
340
468
563
615
608
586
572
90
85
75
65
55
45
35
25
15
5
0
Candelas
Wall Wash
45°
30°15°0°
60°
75°
90°
200
400
600
Candlepower Distribution
2’ from wall
(distance from xture along wall)
2’ from wall
(spacing between xtures)
3’ from wall
(spacing between xtures)
DD
n
1' 2' 3'
n ––––– 2’––––– n n ––––– 3’––––– n n ––––– 3’––––– n n ––––– 4’––––– n
1 27 11 3 1 33 24 34 29 11 29 9 6 9 8 3 8
2 29 17 5 2 41 38 41 33 20 33 17 14 18 12 6 12
3 17 13 6 2 31 31 31 22 19 22 18 17 18 14 9 14
4 10 8 5 2 22 22 22 15 15 15 15 15 15 13 11 13
5 5 5 3 2 15 15 15 10 10 10 12 12 12 10 10 10
6 3 3 2 2 11 11 11 7 8 7 10 10 10 8 8 8
7 2 2 2 1 8 8 8 6 6 6 7 8 7 6 6 6
8 2 1 1 1 6 6 6 4 4 4 6 6 6 5 5 5
9 1 1 1 1 5 5 5 3 3 3 5 5 5 4 4 4
10 1 1 1 1 4 4 4 3 3 3 4 4 4 3 3 3
Efficiency = 36.0%
Test No. 254P240
Platform = P406TAT
Element = E4LWWH
Lumens = 1800
Lamp = CF26TTT/E/830
Photometric Results
Single Unit Footcandles Multiple Unit Footcandles
Zone Lumens
%
Lamp
%
Luminaire
0- 30 272 15.1 42
0- 40 403 22.4 62.3
0- 60 584 32.5 90.3
0- 90 647 36 100
90-180 0 0 0
0-180 647 36 100
Zonal Lumens Summary
CD
Wall
Vertical
Angle
0
3
53
138
233
323
389
424
422
412
404
90
85
75
65
55
45
35
25
15
5
0
Candelas
Wall Wash
45°
30°15°0°
60°
75°
90°
140
280
420
Candlepower Distribution