IRIS P406TAT Indoor Furnishings User Manual


 
IRiS • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
02/28/2008 9:02:28 AM
Specifications and Dimensions subject to change without notice.
ADI070195
.
P406TAT MV4CMH20MR E4PINSR
D FC CB
8' 39 3.6'
9' 31 4.0'
10' 25 4.4'
12.5' 16 5.6'
15' 11 6.7'
Vertical
Angle
CD
90
85
75
65
55
45
35
25
15
5
0
0
1
1
1
1
1
21
110
864
2302
2488
Zone Lumens
%
Lamp
%
Luminaire
0- 30 510 51 96.4
0- 40 524 52.4 99
0- 60 526 52.6 99.4
0- 90 529 52.9 100
90-180 0 0 0
0-180 529 52.9 100
Spacing Criterion = .4
Efficiency = 52.9%
Test No. P11075
Platform = P4
Element = E4PINSR
Lumens = 1000
Lamp = CDM20/MR16/
FL25
20W
CMH MR16
Downlight
45°
30°15°
60°
75°
90°
850
1700
2550
Ceiling
Wall %
RCR
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zonal cavity method -- floor reflectance = 20%
0 63 63 63 63 62 62 62 62 59 59 59 56 56 56 54 54 54 53
1 61 60 59 58 60 59 58 57 57 56 55 55 54 54 53 52 52 51
2 59 57 56 54 58 56 55 54 55 54 53 53 52 51 52 51 50 50
3 57 55 53 52 56 54 53 51 53 52 50 52 51 50 51 50 49 48
4 56 53 51 49 55 52 51 49 51 50 49 50 49 48 49 48 48 47
5 54 51 49 48 53 51 49 47 50 48 47 49 48 47 48 47 46 46
6 53 50 47 46 52 49 47 46 49 47 46 48 46 45 47 46 45 44
7 51 48 46 45 51 48 46 44 47 46 44 47 45 44 46 45 44 43
8 50 47 45 43 50 47 45 43 46 44 43 46 44 43 45 44 43 42
9 49 46 44 42 48 45 43 42 45 43 42 45 43 42 44 43 42 41
10 48 44 42 41 47 44 42 41 44 42 41 44 42 41 43 42 41 40
Photometric Results Candlepower Distribution
Coefficients of Utilization
Cone of Light Zonal Lumens SummaryCandelas
D FC CB
8' 96 2.2'
9' 76 2.5'
10' 62 2.8'
13' 36 3.6'
16' 24 4.4'
Vertical
Angle
CD
90
85
75
65
55
45
35
25
15
5
0
0
1
1
1
1
1
22
61
630
4678
6168
Zone Lumens
%
Lamp
%
Luminaire
0-30 573 57.3 97
0-40 587 58.7 99.2
0-60 589 58.9 99.5
0-90 591 59.1 100
90-180 0 0 0
0-180 591 59.1 100
Spacing Criterion = .3
Efficiency = 59.1%
Test No. P10975
Platform = P4
Element = E4PINSR
Lumens = 1000
Lamp = CMH20/MR16/
G10/SP 12°
20W
CMH MR16
Downlight
45°
30°15°
60°
75°
90°
2100
4200
6300
Ceiling
Wall %
RCR
70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
Zonal cavity method -- floor reflectance = 20%
0 70 70 70 70 69 69 69 69 66 66 66 63 63 63 60 60 60 59
1 68 67 66 65 67 66 65 64 64 63 62 61 61 60 59 59 59 58
2 66 65 63 62 65 64 62 61 62 61 60 60 59 59 59 58 57 57
3 65 63 61 59 64 62 60 59 60 59 58 59 58 57 58 57 56 56
4 63 61 59 57 63 60 58 57 59 58 56 58 57 56 57 56 55 55
5 62 59 57 56 61 59 57 55 58 56 55 57 56 55 56 55 54 54
6 61 58 56 54 60 57 56 54 57 55 54 56 55 54 55 54 53 53
7 60 57 55 53 59 56 54 53 56 54 53 55 54 53 55 53 52 52
8 59 55 53 52 58 55 53 52 55 53 52 54 53 52 54 52 52 51
9 58 54 53 51 57 54 52 51 54 52 51 53 52 51 53 52 51 50
10 57 53 52 50 56 53 52 50 53 51 50 53 51 50 52 51 50 50
Photometric Results Candlepower Distribution
Coefficients of Utilization
Cone of Light Zonal Lumens SummaryCandelas