Ionic Pro TP 300D Air Cleaner User Manual


 
10
300
11
7. Reinstall the UV sheild
according to the following
illustration.
8. First, insert the bottom
of the filter into the air
cleaner and then insert
the top of the filter.
9. Insert the top of the inlet
grill first and then snap in
the lower part of the grill.
REPLACING THE UV LAMP
UV LAMP SAFETY WARNING:
To prevent exposure to ultraviolet light, disconnect power to the unit
before servicing any part of the Therapure
®
300D air purifier.
Before replacing the UV lamp of your Therapure
®
300D
air purifier, turn off and unplug the unit from the electrical
outlet and read all safety instructions and important
warnings in this owner’s manual.
Replace your UV lamp every year. Call 800.875.8577
or visit www.therapureair.com.
1. First turn off and unplug your
Therapure
®
300D air purifier.
With the front of the unit facing
up, pull up the lower end of the
inlet grill and push it toward the
display panel at the top of the
unit as shown below.
2. Remove the permanent filter by
lifting and pulling the string.
3. Remove the screws on
the UV shield by using a
screwdriver. Allow the UV lamp
to cool at least 15 minutes.
4. Remove UV sheild.
5. Gently rotate the lamp a
quarter turn in either direction
until it unlocks from the socket.
The lamp removes and installs
in the same way as a
flourescent light lamp.
Pull out the lamp.
6. Unpack the new UV lamp gently
by handling the ends only.
Starting at one end of the
lamp, then the other, gently
insert the metal pins on the
lamp into the white slotted
socket, one pin at a time. Once
the ends of the lamp are
completely inserted into the
socket, rotate the lamp a
quarter turn until it locks
into place.
cleaning & maintenance
Caution:
Do not touch the glass part of the lamp. Oil from fingertips will decrease the effectiveness
of the lamp.
Never operate the unit without a filter or with a damaged filter. The UV light from the UV
lamp will result in severe damage to eyes and could cause blindness.
UV Lamp Notice Warning
UV Light is harmful to bare skin and eyes and can cause temporary or permanent loss of vision.
Never look directly at the UV lamp while it is illuminated-doing so could cause loss of vision!
TO ORDER A REPLACEMENT UV LAMP
If your UV Lamp(s) is broken or needs replacing, simply contact us at 1.800.875.8577
or visit us online at www.therapureair.com.
Therapure
®
replacement lamp part number is TPG63000.