Page 8 of 8 PH30F-XXX-XXX-C (en)
PN 97999-1381
TROUBLE SHOOTING
Product discharged from exhaust outlet.
Check for diaphragm rupture.
Check tightness of (14) cap screw.
Air bubbles in product discharge.
Check connections of suction plumbing.
Check “O” rings between intake manifold and uid caps.
Check tightness of (14) cap screw.
Motor blows air or stalls.
Check (176) check valve for damage or wear.
Check for restrictions in valve / exhaust.
y
y
y
y
y
y
y
Low output volume, erratic ow or no ow.
Check air supply.
Check for plugged outlet hose.
Check for kinked (restrictive) outlet material hose.
Check for kinked (restrictive) or collapsed inlet material
hose.
Check for pump cavitation - suction pipe should be sized
at least as large as the inlet thread diameter of the pump
for proper ow if high viscosity uids are being pumped.
Suction hose must be a non-collapsing type, capable of
pulling a high volume.
Check all joints on the inlet manifolds and suction con-
nections. These must be air tight.
Inspect the pump for solid objects lodged in the dia-
phragm chamber or the seat area.
y
y
y
y
y
y
y
DIMENSIONAL DATA
Dimensions shown are for reference only, they are displayed in inches and millimeters (mm).
Figure 4
A
B
C
D
N
G
H
J
M
L
F
K
Q - Exhaust Port
R - Material Inlet
R - Material OutletP - Air Inlet
DIMENSIONS
A - 23-1/8” (587.4 mm)
B - 30” (762.0 mm)
C - 12-1/32” (306.4 mm)
D - 2-3/4” (69.9 mm)
F - 15” (381.0 mm)
G - 32” (812.8 mm)
H - 10-5/32” (258.0 mm)
J - 11-21/32" (296.1 mm)
K - 9/16” (14.3 mm)
L - 2-3/4" (69.9 mm)
M - 22-27/32” (580.2 mm)
N - 16" (406.4 mm)
P - 3/4 - 14 N.P.T.
Q - 1-1/2 - 11-1/2 N.P.S.M.
“R” Inlet / Outlet
PH30F-ASS-SXX-C 3 - 8 N.P.T.F. - 1
PH30F-BSS-SXX-C Rp 3 (3 - 11 BSP parallel)