Ingersoll-Rand 66610X-X-C Water Pump User Manual


 
66610X-X-CPage 8 of 8
TROUBLE SHOOTING
Product discharged from exhaust outlet.
S Check for diaphragm rupture.
S Check tightness of (14) diaphragm screw.
Air bubbles in product discharge.
S Check connections of suction plumbing.
S Check O" rings between intake manifold and fluid caps.
S Check tightness of (14) diaphragm screw.
Low output volume, erratic flow, or no flow.
S Check air supply.
S Check for plugged outlet hose.
S Check for kinked (restrictive) outlet material hose.
S Check for kinked (restrictive) or collapsed inlet material hose.
S Check for pump cavitation − suction pipe should be sized at least as
large as the inlet thread diameter of the pump for proper flow if high
viscosity fluids are being pumped. Suction hose must be a non-col-
lapsing type, capable of pulling a high vacuum.
S Check all joints on the inlet manifolds and suction connections.
These must be air tight.
S Inspect the pump for solid objects lodged in the diaphragm chamber
or the seat area.
DIMENSIONAL DATA
(Dimensions shown are for reference only, they are displayed in inches and millimeters (mm).
8" (203 mm)
12-1/2"
(318 mm)
11-9/16"
(294 mm)
8-9/16"
(217.5 mm)
4" (102 mm)
1-1/4" (32 mm)
7-5/16" (186 mm)
Air Inlet
1/4 - 18 N.P.T.F. - 1
13/32" Slot (10 mm)
Figure 5
6-1/4" (159 mm)
6-1/2"
(165 mm)
Outlet
Inlet
1 - 11-1/2 N.P.T.F. - 1 (66610X, 66611X)
Rp 1 (1 - 11 BSP parallel) (66612X, 66613X)
1 - 11-1/2 N.P.T.F. - 1 (66610X, 66611X)
Rp 1 (1 - 11 BSP parallel) (66612X, 66613X)
PN 97999-100