Cornelius PR150/300 Plumbing Product User Manual


 
PR150/300 and IP150 Separate Drain for Upper Driptray Installation Instructions
Publication Number: 629088497INS - 2 - © 2004, IMI Cornelius Inc.
4. Cut PVC drain as shown in FIGURE 5. BE
CAREFUL TO SECURELY HOLD DRAIN LINE
TO AVOID DAMAGE TO UPPER DRIPTRAY!!!
FIGURE 5
5. Deburr edge of PVC and re-plumb and clamp with
new flexible tube/clamp supplied in kit (see
FIGURE 6). MAKE SURE THAT THE
INSULATION COVERS ALL EXPOSED
TUBING/CLAMP!
FIGURE 6
6. Re-route new drain tube to floor drain. MAKE SURE THAT THERE ARE NO KINKS IN NEW
DRAIN LINE!
7. Re-install driptray strainer if applicable.
8. Check driptray, fittings, and lines for leaks.
9. Lower upper driptray assembly.
Cut PVC Drain
Clamp Drain Line
Re-plumb with New Drain
Line and Insulation