Cornelius Door Latch Door User Manual


 
Door Latch Assembly Installation Instructions
© 2004, IMI Cornelius Inc. - 1 - Publication Number: 729011146INS
INSTALLATION INSTRUCTIONS
REMOVAL AND INSTALLATION OF DOOR LATCH ASSEMBLY QUEST
NOTE: Removing the existing door catch/switch with the replacement catch will remove the auto-
matic sold out reset function of the machine. This feature can still be used or totally defeated
depending on users preference.
OPTION 1: By removing the existing switch and not jumping the board the sold out will work, but not
reset unless the pump door switch is manually reset after each refill. If the switch is not manually reset
the light will not go out even after installing new product.
OPTION 2: To disable the sold out feature jumpers are added to the control board in the sold out plug
location. The sold out will now be disabled and never come on.
Installation of these options are described below.
Parts List
Tools Required
• Hex Screw Driver
• Electrical Tape
Description Part Number Qty
Bracket 720201471 1
Sold Out Jumper Board 11749 4
Jumper Switch 720302204 1
Spacer 720705306 1
Screw Plastic #8 x ¾” 07015001 2
Screw 6-32 x 3/8” 0700203 2
Washer .145x.5x .03 07301043 2
Screw 6-32 x 1/4 0700201 2
Latch 720532112 1
Catch 720202415 1
FIGURE 1
Revision Date: June 30, 2004 www.cornelius.com Revision: C