Model Height Height Emitter Length Emitter Output Watts at Δ T50
(mm)
inc Kick Grille Height (mm) Length K1 P+ K2
(mm) (mm) (mm)
500 500 300 650 400 203 290 362
500 500 300 850 600 304 435 542
500 500 300 1050 800 406 580 723
500 500 300 1250 1000 507 725 904
500 500 300 1450 1200 608 870 1085
500 500 300 1650 1400 710 1015 1266
500 500 300 1850 1600 811 1160 1446
500 500 300 2050 1800 913 1305 1627
500 650 400 650 400 264 388 456
500 650 400 850 600 397 581 685
500 650 400 1050 800 529 775 913
500 650 400 1250 1000 661 969 1141
500 650 400 1450 1200 793 1163 1369
500 650 400 1650 1400 925 1357 1597
500 650 400 1850 1600 1058 1550 1825
500 650 400 2050 1800 1190 1744 2054
600 750 400 650 400 336 461 558
600 750 400 850 600 503 692 837
600 750 400 1050 800 671 922 1116
600 750 400 1250 1000 839 1153 1395
600 750 400 1450 1200 1007 1384 1674
600 750 400 1650 1400 1175 1614 1953
600 750 400 1850 1600 1342 1845 2232
600 750 400 2050 1800 1510 2075 2511
Integral Kick GrilleOptional Kick GrilleOptional Kick Grille
Data & Dimensions
Blanking Cap
Each LST 2 has a blanking cap which
can be used to make the LST 2 totally
tamper proof.
TRV - Lockable
The TRV within the LST 2 can be locked
at any temperature within the range so
that performance and comfort levels can
be maintained. Also comes with 2m
remote sensing capiliary as standard.
Kick Grilles
Optional kick grilles are provided on the
two larger models and can be used as
either full unit grilles or simply pipe
cores.
27
LST Plus
ٌ
72 Models
Heights 500, 650, 750mm
Lengths 650 - 2050mm
Output 203 - 2511 watts
Types K1, P+ & K2
Specialised integrated features as standard
Complete pre-assembled package
Unique design ensuring safety