The diagnostic features of the ECS will cover most problems that you may have with
your heater. Table 5 Troubleshooting chart addresses some other problems that may
arise
TABLE 5. TROUBLESHOOTING CHART
Trouble Cause and/or Remedy
Heater fails to start -
motor does not run,
green light is not
on.
1. Check fuse.
2. Check all electrical connections including ground.
3. Check motor. Replace if necessary.
4. Is it turned on?
Heater fails to start -
motor does not run,
green light is on.
1. Check to see if Comfort Control is turned up
)(!
The PH20-30A is designed so that the igniter should
never have to be replaced. If for some reason the
igniter is broken or the burner head requires cleaning
and the igniter is removed, the igniter gap should be
checked. Set the gap to .125” +.03 -00. It is important
that the gap be set correctly for flame ignition and
flame sensing.
To set the spark gap:
1. bend the center electrode
slightly
2. check with feeler gage
between igniter tip and
center electrode
NOTE: igniter should not need
to be bent. Adjust center
electrode only