ATTACHING THE THERMOSTAT
Lift the thermostat cover and set the SYSTEM switch to OFF
and the FAN switch to AUTO.
1. Locate the HE/HG switch on the back of the thermostat.
Set the switch to HG (default) for gas furnace and oil
burners. Set the switch to HE for electric furnaces.
(The switch has no effect when the system is set to
cooling mode.)
2. Locate the Auto Recovery switch on the back of the
thermostat. If you wish to use the Auto Recovery
feature, verify that the switch is in the ENABLE position.
If you do not wish to use this feature, simply change the
switch to the DISABLE position. See pages 44-45 for
more information.
3. System type - Locate the
SyStem type
switch on the
back of the thermostat. Select either STD (Standard) or
HP (Heat Pump) to match your system.
INSTALLING THE THERMOSTAT, CONT.