A SERVICE OF

logo

16
42845-01 • 02/16/10 • Hunter Fan Company
Problem: Nothing happens; fan does not move.
1. Turn power on, replace fuse, or reset breaker.
2. Loosen canopy, check all connections according to the wiring the fan section.
3. Check the plug connection in the switch housing.
4. Push motor reversing switch rmly left or right to ensure that the switch is engaged.
5. Pull the pull chain to ensure it is on.
6. Remove the shipping bumpers.
Problem: Noisy operation.
1. Tighten the blade bracket screws until snug.
2. Tighten the blade screws until snug.
3. Check to see if the blade is cracked. If so, replace all the blades.
4. Change to an approved speed control.
5. Be sure that the glass is secure.
6. Check and tighten the screws in the switch housing mounting plate and in the upper and lower switch
housing.
Problem: Excessive wobbling.
1. If your fan wobbles when operating, use the enclosed balancing kit and instructions to balance the fan.
2. Tighten all blade and/or blade iron screws.
In compliance with Canadian Federal regulations, this ceiling fan contains a wattage saver that limits the
light output to 190 Watts. e following issues may arise if total wattage exceeds 190 Watts:
Issue: Lights dim when turned on.
1. It is normal for the lights to dim a couple of seconds after they are turned
on. To prevent the lights from dimming, make sure the
wattage of light bulbs
installed match the specications on the light sockets.
Issue: Light shuts off suddenly.
1. Turn the power to the fan o at the wall switch. Wait 30
seconds, then resume power to the fan.
2. If lights shut o suddenly again, check to make sure total
wattage of bulbs does not exceed 190 Watts.
If you need parts or service assistance, please call
866-268-1936 or visit us at our Web site at
http://www.hunterfan.com.
Hunter Fan Company
7130 Goodlett Farms Pkwy. #400
Memphis, Tennessee 38016
9 • Troubleshooting