9©2010 Hunter Fan Co. 44025-01 20100616
Figure 14.
5. When the bulb releases, slide the top of the bulb out
of the bracket and remove.
6. Partially remove the new UVC Bulb from it’s packaging
being careful not to let the bulb come in contact with
your skin.
Note: Oils from your skin can cause damage to the bulb
and will prevent it from working.
7. Using the bag the bulb came in to prevent skin contact
with the bulb, insert the base of the bulb into the lower
UVC socket in the unit, with the flat side of the base
facing the opening of the unit. Figure 13.
8. Insert the top part of the UVC bulb into the top socket
and roll the bulb to the right util it locks into place.
Note: If the UVC Bulb Guard is not re-installed correctly,
the unit will not run.
9. Reattach the UVC Guard by inserting the back tabs
into the Air Purifier and secure the 3 screws holding it
back in place. Figure 14.
10. Align the Photocatalytic Screen over the 2 holes in
the unit and screw it back into place.
11. Set the tab on the bottom of the rear grill into the slot
in the base of the unit and rock the grill up until the
top tab snaps into place.
Figure 15.
Clean the Unit
Clean the outside of the unit with a soft, damp cloth.
The rear grill can be cleaned in soapy water after it has
been removed from the unit and the pre-filter has been
removed.
NOTE: Ensure the grill is completely dry before
reinstalling it on the unit. Failure to do so could cause
damage to the filters or motor.
Figure 13.
Figure 12.