Problem:
No Operation.
Solution:
Confirm that the unit is plugged in.
Problem:
Unit has reduced air flow or
increased noise.
Solution:
The filter may be clogged and needs
to be cleaned. (page 5)
TROUBLESHOOTING
Hunter Fan Company
PERMAlife
®
Air Purication
System
5 YEAR LIMITED WARRANTY
The Hunter Fan Company makes the
following limited warranty to the original
residential user or consumer purchaser of the
PermaLife
®
Air Purification System:
If any part of your PermaLife
®
Air Purification
System (“Air Purifier”) motor fails during the
first five (5) years from the date of installation
due to a defect in material or workmanship,
we will provide a replacement Air Purifier free
of charge. Installation is deemed to occur at
the date of purchase.
If the Air Purifier cord, ionizer, or front grill fails
any time within one (1) year after installation
due to a defect in material or workmanship,
we will replace or, at our option, repair the unit
free of charge at our nearest service center
or at our Service Department in Memphis,
Tennessee. You will be responsible for all
parts and labor costs after this one-year
period.
IF THE ORIGINAL RESIDENTIAL USER OR
CONSUMER PURCHASER CEASES TO
OWN THE AIR PURIFIER, THIS WARRANTY
AND ANY IMPLIED WARRANTY WHICH
THEN REMAINS IN EFFECT, INCLUDING
BUT NOT LIMITED TO ANY IMPLIED
WARRANTY OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR
PURPOSE, ARE VOIDED. NO WARRANTY,
If you have any additional questions or
problems with your Hunter Air Purifier, please
call:
USA: 1-888-830-1326
Canada: 1-866-268-1936
Hours of operation are from 7:00 am to 7:00
pm Monday - Friday and 8:00 am to 5:00
pm on Saturday, Central Time. You may also
contact us over the Internet at www.hunterfan.
com.
NOTE: To avoid the risk of electric shock, the
unit should be unplugged before cleaning.
1. Clean the outside of the unit with a soft,
damp cloth. The front grill can be cleaned
in soapy water after it has been removed
from the unit and the pre-filter has been
removed. See Figure 1.
NOTE: Ensure the grill is completely dry
before reinstalling it on the unit. Failure to
do so could cause damage to the filters or
motor.
2. At least every 90 days, open the front grill,
remove the washable pre-filter, and clean
it. If necessary, it can be cleaned more
often. Remember to change the Pre-Filter
Calendar Dial to reflect the new cleaning.
3. The PermaLife
®
filter should be removed
every 6 months of use and cleaned. With
a vacuum cleaner and upholstery brush
attachment, gently run the upholstery brush
over the cleanable filter until all particles
are removed from the filter. An arrow
indicating which side to clean is present on
the top of the filter.
Note: Filter discoloration is normal and will not
be removed by vacuuming. Do not attempt to
wash the filter as damage to the Filter or Air
Purifier may occur.
CLEANING