Human Touch HT-7450 Water Pump User Manual


 
2
INSTALLING THE NEW FITTING
1. Place the new fitting into the air pump tubing connector, and secure it using the two screws.
2. Connect the air pump tubing connector to the corresponding receptacle on the backrest connection panel (located on the back of the left-hand armrest).
3. Plug in the chair and power it on.
4. Verify that the massage comfort control is now working properly.
Please send any questions or comments regarding these instructions to:
documentation@humantouch.com
© 2008 Human Touch
®
, LLC.
White fitting receptacle
Inside of the left-hand
side panel cover
(Fig.5)
Tubing
(Fig.6)
X1103
Fitting
4. If you cannot remove the broken fitting piece from the receptacle, you will need to remove the left-hand side panel,and remove the broken piece from the inside:
a. Using two hands, pull the left-hand side panel cover outward to separate it from the chair (Fig.4).
b. Using a nail clipper or other instrument suitable for cutting zip ties, cut the zip tie that secures the tubing to the white fitting receptacle, then remove the tubing
from the receptacle (Fig.5).
c. Use a small needle-nosed pliers or other similar tool to remove the broken fitting piece from the receptacle.
d. Place the tubing back onto the fitting receptacle, and secure it using a new zip tie.
e. Align the posts on the chair base with the corresponding post guides on the side panel cover, then gently tap the cover into place.
5. Using a Phillips-head screwdriver, remove the two screws that secure the fitting to the air pump tubing connector (Fig.6).
Left-hand side panel cover
(Fig.4)