Hoover Breeze Vacuum Cleaner User Manual


 
CHANGING THE BELT OR BRUSHES CLEARING A BLOCKAGE
IMPORTANT: Switch the cleaner off and
remove the plug from the electricity supply
before dismantling cleaner
IMPORTANT: Switch the cleaner off and
remove the plug from the electricity supply
before dismantling cleaner
If your cleaner is not picking up efciently, the belt or brushes (or both) may need replacing, but rst please make
sure you have:
• Emptied the dust container
• Cleaned the lters
• Checked for blockages
Turn the cleaner over and remove 6
retaining screws attaching the brush guard
to the base.
Remove the brush guard
Hold the brush assembly and stretch the
belt until the brush can be slotted back
into the cleaner housing.
Rotate the brush to ensure free movement
of the belt.
Refit the brush guard with 6 retaining screws.
1 4
2
3
5
6
If cleaning tools were
in use, check the
cleaning tool and the
hose.
Check the hose by
removing it from the
cleaner.
Turn the cleaner
over and rotate the
brushes until they
are free to rotate.
Check for a blockage in
the hose socket. Use a
flexible rod to remove
any obstruction.
To remove a blockage
from the Pet Hair &
Allergen Remover*,
open the nozzle at each
side, lift cover and remove
the blockage.
- 7 -
*Certain models only
Remove brush assembly and check for
wear on the belt.
Loop the new
belt around the
motor and brush channel.
Breeze manual.indd 7 5/1/2012 2:03:20 PM