Honeywell VISTA-250BP Home Security System User Manual


 
19
Security Codes & Authority Levels (contd)
MULTI-ACCESS ?
0 = NO , 1 = YES
If you as a user have access to other partitions, the
keypad will prompt for ability of this new user to
access (GOTO) those partitions. Press 0 (NO) or 1
(YES). If no, the system activates this user code and
exits Add a User mode. If yes, the keypad prompts
for the Global Arm option for this user.
GLOBAL ARM ?
0 = NO , 1 = YES
Press 1 (YES) if this user will be allowed to try to
arm more than one partition at the same time.
Press 0 if this user will arm only his assigned
partition.
PART.2 - SHOP?
0 = NO , 1 = YES
The keypad now prompts for the users access to the
next partition (see GOTO command). Again press 0
or 1. If yes, the system will automatically assign a
user number for use in that partition and will
prompt for authority level and global arm options
for this user within the partition (see previous
steps).
XMIT USER DATA?
0 = NO , 1 = YES
If the user number is from 001-050 this prompt
appears. Answer YES (1) to have the system send
the users attributes to all the other control panels
that are linked to this control. If you answer NO
(0), the system displays the following prompt on the
next page.
INDV USER PGM
1 = YES 0 = NO
Answer YES (1) to link to another control panel and
manually enter the user into partition(s) in that
control panel. If you answer NO (0), the system
scrolls through each partition displaying a
summary of the users attributes in each partition
(see next prompt).