Honeywell VISTA-21IP Home Security System User Manual


 
10
About The Keypads (Cont’d)
FIXED-WORD DISPLAY KEYPAD
AWAY: All burglary zones, interior and
perimeter, are armed.
STAY: Perimeter burglary zones, such as
protected windows and doors, are
armed.
NIGHT-STAY: NIGHT and STAY indicators both
light when perimeter burglary
zones plus pre-selected interior
zones (set by the installer) are
armed.
INSTANT: Entry delay is turned off:
Lit with STAY = Instant mode
Lit with AWAY = Maximum mode
ALARM
FIRE
AWAY
BYPASS
STAY
CHECK INSTANT CANCELED
NIGHT NO AC
NOT READY
CHIME BAT
PHONE TEST
6150disp
FIXED-WORD DISPLAY
BYPASS: This appears when one or more burglary protection zones have been
bypassed.
NOT READY: Appears when burglary portion of the system is not ready for arming (due
to open protection zones). The system is ready to arm when this message
disappears and the READY indicator light comes on.
NO AC: Appears when AC power has been cut off. System is operating on backup
battery power.
AC: Appears when AC power is present.
CHIME: Appears when the chime feature is activated.
BAT: Low battery condition in a wireless sensor (if zone number displayed) or
low system battery (if no zone number displayed).
ALARM: Appears when an intrusion has been detected and the system is armed
(also appears during a fire alarm or audible emergency alarm).
Accompanied by the protection zone in alarm.
CHECK: Appears when a malfunction is discovered in the system at any time, or if
an open is detected in a fire zone at any time, or a fault in a DAY/NIGHT
burglary zone during a disarmed period. Accompanied by a display of
zone number in trouble.
FIRE: Appears when a fire alarm is generated. Accompanied by a display of the
zone in alarm.
A FIRE display also appears when a fire alarm is manually activated,
accompanied by a display of the fire emergency key zone number.
CANCELED: Appears when an alarm has been silenced by the Code + OFF sequence
and will remain on until another Code + OFF sequence is keyed.