Honeywell V8043 Thermostat User Manual


 
7
8
A
B
C
D
THERMOSTAT
END SWITCH
V8043F
TH-TR
TH
TR
L1
(HOT)
L2
1
E
M5960
A
B
C
D
THERMOSTAT
END SWITCH
V8043F
TH-TR
TH
TR
L1
(HOT)
L2
1
E
TO
AUXILIARY
CIRCUITS
TO
AUXILIARY
CIRCUITS
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.
1
Fig. 17 - Wiring Honeywell V8043F to Taco System (two options).
(Wires are identified with letters to correspond with wires in Fig. 15.)
L1
(HOT)
L2
1
A
B
F
D
E
THERMOSTAT
DOLE VALVE
TO TERMINALS
T, T ON
BURNER RELAY
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
M5977
1
2
3
4
C
L1
(HOT)
L2
1
A
B
C
D
E
THERMOSTAT
V8043E
TO TERMINALS
T, T ON
BURNER RELAY
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
M5965
YELLOW
YELLOW
RED
RED
F
A
B
C
F
THERMOSTAT
END SWITCH
V8043F
TH-TR
TH
TR
L1
(HOT)
L2
1
E
M5966
A
B
C
F
THERMOSTAT
END SWITCH
V8043F
TH-TR
TH
TR
L1
(HOT)
L2
1
E
TO TERMINALS
T, T ON
BURNER RELAY
TO TERMINALS
T, T ON
BURNER RELAY
D
D
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.
1
M5978
A
B
C
D
THERMOSTAT
FLAIR VALVE
L1
(HOT)
L2
1
F
TO TERMINALS
T, T ON
BURNER RELAY
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.
1
E
3
2
1
4
5
Fig. 18 - Existing Dole System. (Wires are identified with letters to
correspond with wires in Fig. 19 and 20.)
Fig. 19 - Wiring Honeywell V8043E to Dole System. (Wires are
identified with letters to correspond with wires in Fig. 18.)
Fig.20 -. Wiring Honeywell V8043F to Dole System (two options).
(Wires are identified with letters to correspond with wires in Fig. 18.)
Fig. 21 - Existing Flair System. (Wires are identified with
letters to correspond with wires in Fig. 22 and 23.)
L1
(HOT)
L2
1
A
B
C
D
E
THERMOSTAT
V8043E
TO TERMINALS
T, T ON
BURNER RELAY
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
M5965
YELLOW
YELLOW
RED
RED
F
Fig. 22 - Wiring Honeywell V8043F to Flair System. (Wires are
identified with letters to correspond with wires in Fig. 21.)
A
B
C
F
THERMOSTAT
END SWITCH
V8043F
TH-TR
TH
TR
L1
(HOT)
L2
1
E
M5966
A
B
C
F
THERMOSTAT
END SWITCH
V8043F
TH-TR
TH
TR
L1
(HOT)
L2
1
E
TO TERMINALS
T, T ON
BURNER RELAY
TO TERMINALS
T, T ON
BURNER RELAY
D
D
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.
1
Fig. 23 - Wiring Honeywell V8043F to Flair System (two options).
(Wires are identified with lettersto correspond with wires in Fig. 21.)
WATER VALVE
THERMOSTAT
WHITE-RODGERS
1311 OR 1321
VALVE
TO AUXILIARY
CIRCUIT
L1
(HOT)
L2
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.
M5711
1
2
3
4
5
6
4
56
1
1
L1
(HOT)
L2
THERMOSTAT
TO AUXILIARY
CIRCUIT
YELLOW
RED
RED
TO 6 ON
THERMOSTAT
TO
AUXILIARY
CIRCUIT
YELLOW
YELLOW
RED
RED
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.
IF TRANSFORMER SUPPLIES POWER TO AUXILIARY CIRCUIT,
WIRE AUXILIARY CIRCUIT AS SHOWN IN LOWER DIAGRAM.
TAPE UNUSED END AND TUCK INTO HOLE.
1
2
3
5
4
6
M5712
1
2
3
1
L1
(HOT)
L2
Fig. 25 - Wiring Honeywell V8243E to White-Rodgers System.
Fig. 24 - Existing White-Rodgers System.
TO AUXILIARY
CIRCUITS
V8043F
END SWITCH
TH-TR
TH
TR
5
4
6
1
2
3
THERMOSTAT
L1
(HOT)
L2
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.
IF TRANSFORMER SUPPLIES POWER TO AUXILIARY CIRCUIT,
WIRE AUXILIARY CIRCUIT AS SHOWN IN LOWER DIAGRAM.
TAPE UNUSED END AND TUCK INTO HOLE.
1
2
3
TH
TR
TH-TR
END SWITCH
1
2
L1
(HOT)
L2
M5713
TO AUXILIARY
CIRCUITS
THERMOSTAT
END SWITCH
L1
(HOT)
L2
V8043F
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.
IF TRANSFORMER SUPPLIES POWER TO AUXILIARY CIRCUIT,
WIRE AUXILIARY CIRCUIT AS SHOWN IN LOWER DIAGRAM.
TAPE UNUSED END AND TUCK INTO HOLE.
1
2
3
1
2
3
4
5
6
L1
(HOT)
L2
1
TO
AUXILIARY
CIRCUIT
TO
AUXILIARY
CIRCUIT
2
END SWITCH
TH-TR
TH TR
M5714
Fig. 26 - Wiring Honeywell V8043F to White-Rodgers System
(one option).
Fig. 27 - Wiring Honeywell V8043F to White-Rodgers System
(alternate option).