Honeywell TL6120 Thermostat User Manual


 
TL6120 69-1904EF 1/16/06 2/2
To use this mode, press the button until MAN is
selected (outlined) on the screen. Then, set the desired
temperature using the buttons.
In this mode, any modification to the temperature
setpoint must be done manually.
To use the economy mode, press the button until
ECONO is selected (outlined) on the screen. This
mode is ideal for weekend residences as it can be
used as follows: The temperature is kept at an
economy level during most of your absence and is
raised to a comfortable level by your usual arrival. If
you do not show up, the temperature returns to the
economy level until next weekend.
The economy mode has two periods which should be set as follows:
The economy mode should be used as follows:
Place the thermostat in economy mode during your absence.
When you arrive, place the thermostat in automatic mode or in
manual mode before the temperature drops back to the
economy level.
When you leave, switch the thermostat back to economy mode.
To program the two periods of the economy mode:
n Press the button until ECONO is selected.
o Press the button. Period 1 is displayed.
p Set the start day for the period using the button.
q Set the start time using the and buttons.
r Set the temperature for the period using the buttons.
s Press to select period 2.
t Repeat steps 3 to 5 to set the day, time and temperature for
period 2.
u Press to return the thermostat to normal display.
During a power outage, the thermostat display remains lit for
approximately the first 15 minutes during which the LP (low power)
indicator appears. The settings are saved in memory. However, if the
power failure exceeds 5 hours, only the thermostat’s clock must be
re-adjusted. When power returns, the thermostat returns to the mode
of operation preceding the power outage.
Supply: 240 VAC, 50/60 Hz
Minimum load: 500 W (2 A resistive only)
Maximum load: 3000 W (12.5 A resistive only)
Display range: 0°C to 70°C (32°F to 99°F)
Setpoint range: 5°C to 27°C (40°F to 80°F)
Resolution: 1°C (1°F)
Storage: -20°C to 50°C (-4°F to 120°F)
Dimensions: 126 x 121 x 33 mm (5.0 x 4.8 x 1.3 inches)
Approval: c UL us
Honeywell warrants this product, excluding battery, to be free from defects in the
workmanship or materials, under normal use and service, for a period of five (5) years
from the date of purchase by the consumer. If at any time during the warranty period the
product is determined to be defective or malfunctions, Honeywell shall repair or replace it
(at Honeywell's option).
If the product is defective,
(i) return it, with a bill of sale or other dated proof of purchase, to the place from which
you purchased it, or
(ii) call Honeywell Customer Care at 1-800-468-1502. Customer Care will make the
determination whether the product should be returned to the following address:
Honeywell Return Goods, Dock 4 MN10-3860, 1885 Douglas Dr N, Golden Valley,
MN 55422, or whether a replacement product can be sent to you.
This warranty does not cover removal or reinstallation costs. This warranty shall not
apply if it is shown by Honeywell that the defect or malfunction was caused by damage
which occurred while the product was in the possession of a consumer.
Honeywell's sole responsibility shall be to repair or replace the product within the terms
stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF
ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES
RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY,
EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states
do not allow the exclusion or limitation of incidental or consequential damages, so this
limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON
THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, IS HEREBY LIMITED TO THE FIVE-YEAR DURATION OF THIS
WARRANTY. Some states do not allow limitations on how long an implied warranty lasts,
so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which vary
from state to state.
If you have any questions concerning this warranty, please write Honeywell Customer
Relations, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-468-1502. In
Canada, write Retail Products ON15-02H, Honeywell Limited/Honeywell Limitée, 35
Dynamic Drive, Scarborough, Ontario M1V4Z9.
If you have any questions about the operation of your thermostat, please go to http://
yourhome.honeywell.com, or call Honeywell Customer Care toll-free at 1-800-468-
1502.
q
Manual (hold) mode
4.
r
Economy mode
5.
Period Temperature Setting Start Time Setting
1
Set to a comfortable
level.
Set a time where the temperature
starts to rise to reach a comforta-
ble level by the time you arrive.
2
Set to an economy
level.
Set a time where the temperature
starts to drop to an economy level
if you do not show up.
s
Power Outage
6.
t
Troubleshooting
7.
PROBLEM SOLUTIONS
Thermostat is hot.
Under normal operation, the thermostat housing
may reach a temperature between 35°C (95°F)
and 40°C (104°F).
Wrong temperature is dis-
played.
Verify that the sticker on the thermostat’s screen
has been removed. If the thermostat is exposed to
air draft, eliminate the draft.
Wrong time is displayed.
The thermostat was probably without power for
more than 5 hours.
Temperature does not change
according to the programmed
schedule.
Check that the thermostat is in automatic mode.
Check the schedule and clock settings.
The normal display disappears
and reappears after a few min-
utes.
The thermal protection device on the heater might
be open. This can happen if the heater is
obstructed by furniture or curtains and has over-
heated.
u
Specifications
8.
;
Warranty
9.
Customer Assistance
10.
As an ENERGY STAR
®
partner, Honeywell has
determined that this product meets the E
NERGY STAR
guidelines for energy efficiency.