Honeywell TL6120 Thermostat User Manual


 
TL6120 69-1904EF 1/16/06 1/2
The TL6120 thermostat can be used to control an electric heating
system such as a baseboard heater, a radiant floor, a radiant ceiling,
a convector, a fan-forced heater, etc.
The clock must be set when TIME flashes on the screen.
n Press the button to set the day.
o Use the and buttons to set the clock.
p Press the button to exit.
To use the Automatic mode, press the button until
AUTO is selected (outlined) on the screen. The current
period number will appear.
In this mode, the thermostat automatically adjust its
temperature setpoint according to the period of the day
(wake up, leave for work, return home and sleep).
You can program up to 4 periods in a day. You can set 2 different
programs: one for the weekdays (Monday to Friday) and another one
for the weekend (Saturday and Sunday).
The thermostat is preprogrammed with the following schedule:
To temporarily override the current setpoint, set the desired
temperature using the buttons. The new setpoint will be used
until the beginning of the next period.
To modify the schedule:
n Press the button until AUTO is selected.
o Press the button.
Each time you press the button, the thermostat displays one of
the periods in the following order (from left to right):
p Set the start time for the period using the and buttons.
NOTE: To disactivate the period, press the button. Instead
of displaying the start time of the period, the thermostat will dis-
play --:--. During operation, the thermostat will skip over that
period.
q Set the temperature for the period using the buttons.
r Repeat steps 2 to 4 for the remaining periods.
s Press the button to return the thermostat to normal display.
TL6120
User Guide
5-2 Programmable Thermostat
Period no. in
automatic mode
Temperature *
Heating power
indicator
Time and day
Manual
mode
Automatic
mode
Economy
mode
Period no. in
economy mode
Appears if the
thermostat is configured
for a fan-forced heater
Appears during
a power failure
Appears when the
setpoint is displayed
Flashes when the
clock has been reset
Display
* The thermostat normally displays the actual (measured) temperature.
To view the set temperature (setpoint), press either of the buttons once.
Up/Down buttons
Mode button
Day button
Hour button
Program button
Return button
Screen
Minute button
Pull cover down
n
Description
1.
o
Clock and Day Setting
2.
p
Automatic (programmable) mode
3.
Period Monday to Friday Saturday & Sunday
Start Time Temperature Start Time Temperature
1 Wake 6:00 21°C (70°F) 6:00 21°C (70°F)
2 Leave 8:00 16°C (62°F) -- --
3 Return 18:00 21°C (70°F) -- --
4 Sleep 22:00 16°C (62°F) 22:00 16°C (62°F)
Monday to Friday Saturday and Sunday
MO TU WE TH FR SA SU
12341234