Honeywell TH8320U Thermostat User Manual


 
VisionPRO
TM
TH8000 Series
7
69-2693—01
ENGLISH
DONE
20
0120
DONE
20
0120
MCR29486
Installer setup
SettingFunction
Press DONE to exit & save settings.
Press st to
select function
Press st to
change setting
Setup functions Settings & Options (factory default in bold)
Shaded areas below apply only to TH8320/TH8321.
0120 Year
(rst two digits)
20 (2001-2099)
21 (2100-2178)
0130 Year
(second two digits)
12 (2012)
[Otheroptions:00-99]
0140 Month 6 [Otheroptions:1-12]
0150 Date 15 [Otheroptions:1-31]
0160 Schedule format 4 7-day programming
0 Non-programmable
0170 System type 1 1 heat/1 cool conventional
2 1heat/1coolheatpump(noaux.heat)
3 Heatonly(2-wiresystems)
4 Heatonlywithfan
5 HotwaterSeries20system(powertoopen&closezone
valves/normallyopenzonevalves)
6 Coolonly
7 2heat/1coolheatpump(withaux.heat)
8 2heat/2coolmultistageconventional
9 2heat/1coolmultistageconventional
10 1heat/2coolmultistageconventional
11 2heat/2coolheatpump(noaux.heat)
12 3heat/2coolheatpump(withaux.heat)
0180 Fan control
(heating)
0 Gas/Oil heat (equipment controls heating fan)
1 Electricfurnace(thermostatcontrolsheatingfan)
0190 Changeover valve
(O/B terminal)
0 O/B terminal controls valve in cooling
1 O/Bterminalcontrolsvalveinheating
0200 Auxiliary heat 0 Electric backup heat
1 Fossilfuelbackupheat
0210 External fossil
fuel kit
1 External fossil fuel kit controls backup heat
0 Thermostat controls backup heat (outdoor sensor required)
0220 1st stage com-
pressor cycle rate
3 Recommended for most compressors
[Otheroptions:1,2,4,5or6CPH]
0230 2nd stage com-
pressor cycle rate
3 Recommended for most compressors
[Otheroptions:1,2,4,5or6CPH]
Continued on next page