Auto Changeover(SetupFunction0300):WhensettoAuto,thethermostatautomaticallyselectsheating
orcoolingdependingontheindoortemperature.Heatandcoolsettingsmustbeatleast2degreesapart.If
function0380issettoOn,theheatandcoolsettingsmustbeatleast5degreesapart.
Remote Sensor(SetupFunction0340):Ifanoptionaloutdoorsensorisinstalled,thethermostatcan
displaytheoutsidetemperature.Ifanoptionalremoteindoorsensorisinstalled,thethermostatwilldisplay
the temperature at the sensor location (the internal sensor in the thermostat is not used).
Adaptive Intelligent Recovery(SetupFunction0530):Allowsthethermostatto“learn”howlongthe
furnaceandairconditionertaketoreachprogrammedtemperaturesettings,sothetemperatureisreached
at the scheduled time.
Compressor Protection(SetupFunction0580):Forcesthecompressortowaitafewminutesbefore
restarting,topreventdamage.Duringthistime,themessage“Wait”ashesonthedisplay.
Heat Pump Temperature Lockout (with fossil-fuelbackup):Ifthethermostatisinstalledwithanoptional
outdoorsensor,youcanselectacompressorlockouttemperature(Function0350).Whentheoutdoortem-
peratureisbelowthelockouttemperature,onlytheauxiliaryheatoperates.Whentheoutdoortemperature
isabovethelockouttemperature,onlythecompressoroperates.
Heat Pump Temperature Lockouts (with electric heatbackup):Ifthethermostatisinstalledwithan
optionaloutdoorsensor,youcanselectacompressorlockouttemperature(Function0350)and/oranaux-
iliaryheatlockouttemperature(Function0360).Whentheoutdoortemperatureisbelowthecompressor
lockouttemperature,onlytheauxiliaryheatoperates.Whentheoutdoortemperatureisabovetheauxiliary
lockouttemperature,onlythecompressoroperates.Iftheoutdoortemperatureisbetweenthecompressor
andauxiliarylockouttemperatures,boththecompressorandauxiliaryheatcanoperate.
Shaded areas below apply only to TH7220.
Special functions
Please contact your distributor to order replacement parts.
Outdoor temperature sensor ................................. PartNumberC7089U1006
Remote indoor temperature sensor ...................... PartNumberC7189U1005
Cover plate* .............................................................PartNumber50002883-001
*(Usetocovermarksleftbyoldthermostats.)