Honeywell TH6320U Thermostat User Manual


 
FocusPRO
®
TH6000 Series
7 69-1920EFS—01
ENGLISH
10
0
MCR29455
System test System status
Shaded areas below apply only to TH6320U/TH6220D or as otherwise noted.
Press s / t to turn system on/off.
Press NEXT to advance to next test.
PressDONEtoterminatesystemtest.
Test number System status
Tobegin,press and hold the s and t
buttons until the display changes.
Installer setup
Setup function Settings & options (factory default in bold)
Shaded areas below apply only to TH6320U/TH6220D or as otherwise noted.
9 Stage 1 compressor
cycle rate (CPH)
3 Recommended for most compressors
[Othercyclerateoptions:1,2,4,5or6CPH]
10 Stage 2 compressor
cycle rate (CPH)
3 Recommended for most compressors
[Othercyclerateoptions:1,2,4,5or6CPH]
12 Manual/Auto
changeover
0 Manual changeover (Heat/Cool/Off)
1 Auto changeover (Heat/Cool/Auto/Off) **See page 8
2 Auto changeover only (Auto) **See page 8
13 Adaptive Intelligent
Recovery
1 On**See page 8
0 Off
14 Temperature
display
0 Fahrenheit
1 Celsius
15 Compressor
protection
5 Five-minute compressor off time **See page 8
[Otheroptions:0,1,2,3or4-minuteofftime]
16 Schedule format 0 5/2 (programmable weekdays and weekends)
1 5/1/1(weekdays,Saturday&Sundayprogrammable)
27 Heat temperature
range stops
90 Max. heat temperature setting is 90° F (32° C)
[Other options: 40 °F to 89 °F (4.5 °Cto31.5°C)]
28 Cool temperature
range stops
50 Min. cool temperature setting is 50° F (10° C)
[Other options: 51 °F to 99 °F (10.5 °Cto37°C)]
Installer system test
10 Heating system 0 Heat and fan turn off.
1 Stage1heatturnson.FanturnsonifSetupFunction1issetto1,
5,9or10ORSetupFunction3issetto1**Seepage6
2 Stage 2 heat turns on
3 Stage3heatturnson-TH6320U only
20 Emergency heating
system
0 Heat and fan turn off
1 Heat and fan turn on
2 Stage 2 heat turns on (auxiliary heat) - TH6220D only
30 Cooling system 0 Compressor and fan turn off
1 Compressor and fan turn on
2 Stage 2 compressor turns on
40 Fan system 0 Fan turns off
1 Fan turns on
CAUTION: Compressor protection is bypassed during testing. To prevent equipment
damage,avoidcyclingthecompressorquickly.