Honeywell S8610 Water Pump User Manual


 
5 69-0463
Fig. 3S8600A,B; S8610A,B connections in a heating system with an atmospheric burner.
Fig. 2S8600F,H,M; S8610F,H with a vent damper plug in a heating system with an atmospheric burner and a D80D
vent damper.
Q345, Q346,
Q348, Q362, Q381
PILOT BURNER/
IGNITER-SENSOR
L1
(HOT)
L2
THERMO-
STAT
1
LIMIT
CONTROLLER
2
4
MV MV/PV PV
GND
(BURNER)
24V
GND
24V TH-W
VENT
DAMPER
PLUG
SPARK
5
S8600F,H,M; S8610F,H
3
POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
ALTERNATE LIMIT CONTROLLER LOCATION.
MAXIMUM CABLE LENGTH 3 FEET [0.9 METERS].
CONTROLS IN 24V CIRCUIT MUST NOT BE IN
GROUND LEG TO TRANSFORMER.
REMOVE PLUG ONLY IF USING VENT DAMPER.
FUSE BLOWS ON STARTUP WHEN PLUG IS REMOVED;
THEN MODULE WILL OPERATE ONLY WHEN VENT
DAMPER IS CONNECTED.
1
2
3
4
5
M1176D
197516A
WIRING
HARNESS
D80D VENT
DAMPER
2ND
OPERATOR
1ST
OPERATOR
PILOT COM
MAIN
VALVE
DUAL VALVE COMBINATION
GAS CONTROL
PILOT BURNER
GROUND
PILOT GAS
SUPPLY
MV MV/PV PV
GND
(BURNER)
24V
GND
24V
SPARK
S8600A,B; S8610A,B
POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
ALTERNATE LIMIT CONTROLLER LOCATION.
MAXIMUM CABLE LENGTH 3 ft [0.9 m].
CONTROLS IN 24V CIRCUIT MUST NOT BE IN
GROUND LEG TO TRANSFORMER.
FOR MODULE WITH TH-W TERMINAL AND VENT
DAMPER PLUG, CONNECT THERMOSTAT TO TH-W.
LEAVE 24V OPEN. DO NOT REMOVE VENT DAMPER PLUG.
1
2
3
4
5
M1186C
GROUND
PILOT GAS
SUPPLY
2
4
3
SENSOR
IGNITER
SENSE
L1
(HOT)
1
L2
LIMIT
CONTROLLER
THERMOSTAT
5
TH-W
(OPT)
VENT
DAMPER
PLUG (OPT)
5
2ND
OPERATOR
1ST
OPERATOR
PILOT COM
MAIN
VALVE
DUAL VALVE COMBINATION
GAS CONTROL