RTH2510/RTH2410
15 69-2725ES—01
About your new thermostatBuilt-in compressor protection
This feature helps prevent damage to the com-
pressor in your air conditioning or heat pump
system.
Damagecanoccurifthecompressorisrestarted
too soon after shutdown. This feature forces the
compressor to wait 5 minutes before restarting.
Duringthewaittime,thedisplaywillflashthe
message CoolOn (or HeatOn if you have
a heat pump). When the safe wait time has
elapsed, the message stops flashing and the
compressor turns on.
Message flashes until safe restart
time has elapsed.
We
Wake
am
Cool
75
On
6
:
30
M32711