Honeywell PDX50S60F(B,S,C)*(N,X) Water Heater User Manual


 
PDX SERVICE PROCEDURE IX
120 VAC Trace
WARNING
120 volt potential exposure. Use caution
making voltage checks to avoid personal injury.
Disconnect cord set as
shown in photo 26
LED status
None, Control LED not
on or flashing.
Step 1. Verify 120VAC and proper polarity at wall outlet.
Step 2. With unit plugged in and control power switch in the “ON position verify LED status.
LED status
Short flash, once ever y
four seconds.
LED status
“Heartbeat”, alternates
bright/dim.
LED status
Various flashing error
codes.
Waiting for
call for heat.
Thermostat calling
for heat
Verify error code as
listed on page 12
Using a volt meter set to
volts AC, is there 120VAC
across terminals shown
in photo 27 ?
N
Y
26
27
Reconnect cord set
shown in photo 26.
Repair damage
Check for damage to AC
supply power cord.
Y
N
Replace Blower
30
Check for 120VAC between black & white wires.
-NOTE-
Electronic meter probes required. Use care not to
damage connector during this check.
Wire sheath pulled back to
identify wire colors
29
Wire harness
Disconnect wire harness
from gas control
(see photo 29).
Locate black & white wires at connector, It
may be necessary to pull back wire sheath
to identify wire colors.
(see photo 30)
Y
N
Replace gas
control.
Is there 120VAC across
black & white wires as
shown in photo 30?
Call for technical
support.
Is there 120VAC across
terminals shown in
photo 28 ?
N
Y
Incorrect supply
voltage polarity
28
Page 30
120 VAC Circuit Trace
PDX Series
30