Honeywell PCR-100 Thermostat User Manual


 
14
Control performance: Two-step
Display accuracy: ± 0.5 K internal, ±1 digit, at 25 °C
Operating conditions: 0 to 50 °C, 30 to 85 % R.H.,
excluding dew
Storage temperature: –20 to +80 °C
Data back-up: Non-volatile memory (EEPROM)
Sensor: 1 PTC
– Sensor cable length: 2.5 m
– Range where cable –30 °C to +80 °C not fixed
can be used: –40 °C to +80 °C fixed
– Sensor accuracy: ±2 %
Housing: PCR-100: L x W x H = 85 x 70 x 61 mm
PCR-110: L x W x H = 70 x 74 x 32 mm
ABS plastic, self-extinguishing
(UL 94 V0)
Protective rating: Housing: IP 20, Front panel: IP 52
Class of protection 2
Terminals: 10 A screw-type terminal strips,
with wire protection,
tightening torque 0.6 Nm
Max. core cross section 1.5 mm
2
Weight: PCR-100: Approx. 330 g (inc. sensor).
PCR-110: Approx. 240 g (inc. sensor).
Only operate the unit in dry places.
Errors in the technical data are excepted. We reserve the right to make
changes without prior notice.