Honeywell MM14CHCS Air Conditioner User Manual


 
When there is excess water condensation inside the unit, the air conditioner stops running and
shows a warning light (refer to page 10). This warning light indicates that the water condensation
needs to be drained using the following procedures:
WATER CONDENSATION DRAINAGE
14
Continuous Draining
While using the unit in dehumidifier mode, continuous drainage is
recommended.
Upper
Drain Plug
Unplug the unit from power source.
Place a shallow pan under the lower drain plug. See diagram.
Remove the lower drain plug.
Water will drain out and collect in the shallow pan.
After the water is drained, replace the lower drain plug firmly.
You can now turn on the unit.
Manual Draining
Water Condensation Drainage
1.
2.
3.
4.
5.
6.
Unplug the unit from the power source.
Remove the upper drain plug. While doing this operation some
residual water may spill so please have a pan to collect the water.
Connect the drain connector to a ¾” hose (not included).
See diagram.
The water can be continuously drained through the hose into a
floor drain or bucket.
You can now turn on the unit.
1.
2.
3.
4.
5.
Lower
Drain Plug
Water may need to be drained in high humidity areas
Shallow Pan
(Not included)
Water Drain Pipe