Honeywell MM14CCS Air Conditioner User Manual


 
11
USE & OPERATION
Fan Mode
When fan mode is selected the indicator light will shine.
Air is circulated throughout the room with no cooling.
Note: unit does not need to be vented in Fan mode.
Fan Speed Control
The Fan Speed Control has 3 settings: High, Medium,
and Low.
In cooling mode, when “ “ or “ “ button is pressed, the set
temperature is displayed and may be adjusted.
After 10 seconds the display will revert back to room
temperature. Temperature is only adjustable in cool mode.
The time is adjustable between 1~24 hours.
Timer
Auto turn off :
Auto turn on :
With machine in running mode, press timer button to select
number of hours you would like the unit to run in air
conditioning mode until it automatically shuts off.
With machine in stand by mode, press timer button to select
number of hours until you would like the unit to automatically
start running in air conditioning mode.
Timer / Temp set controls
• Used for adjusting the timer and thermostat.
• The default display is room temperature.
Note : By pressing both “ “ / “ “ set buttons at the same
time, the display will toggle between Celsius and Fahrenheit.
Warning Light
Condensed water may accumulate in the unit. If the internal
tank becomes full, the Power Light will flash and the unit will
not operate until the unit has been drained.
Power Control
The power control turns the unit on and off.
Mode Control
The Mode Control has 3 settings:
Cool Dehumidify Fan
The settings are adjusted with Mode Control button. A light
will indicate which setting is currently being used.
Cooling Mode
When cooling mode is selected, the indicator light will shine.
During the cooling mode the air is cooled and hot air is
exhausted to the outside through the exhaust tube.
Adjust fan speed and air temperature to suit your desired
comfort level. Temperature setting range is 16°C ~ 32°C.
Note : The air exchange hoses must vent outside the
room when using cool mode.
• Dehumidify Mode
When dehumidify mode is selected, the indicator light will
shine. Air is dehumidified as it passes through the unit,
without being in full cooling mode If room temperature is
higher than 25 degree Celsius, fan speed can be adjusted;
otherwise fan speed is fixed to " LOW ".
Note : If the unit will be used mainly as dehumidifier, do
not connect the exhaust hose and let the warm air return
in the room. Continuous drainage is then necessary and
more efficient.
After switching the air conditioner off, you must wait 3 minutes before switching it back on again.