Honeywell HE365A Humidifier User Manual


 
HE365A,B POWERED FLOW-THROUGH HUMIDIFIER
3 69-1427-3
OPERATING YOUR HUMIDIFIER
HE365A
Your Enviracaire Elite™ HE365A Humidifier from
Honeywell is controlled by the H8908B Convertible
Humidity Control. The convertible humidity control is
installed either on an interior wall in the living area, or
on the return air duct. Choose the humidity control
setting using the combination relative humidity/
outdoor temperature setting scale on your humidity
control dial. Match the dial setting to the outdoor
temperature for optimizing the humidity level while
reducing the moisture condensation on your windows.
The table below can also be used to adjust the
humidity control to the recommended setting.
NOTE: As the outside temperature drops, the recommended humidity control setting
is lowered to accommodate for effects of dewpoint. These settings should
reduce the accumulation of moisture and ice on your windows and in other
areas of your home.
Some indoor activities such as cooking, showering and clothes drying can cause
excessive levels of humidity and start the accumulation of moisture on your windows.
NOTE: If this condition persists for more than a few hours, set the humidity control to
the lowest setting to turn off the humidifier. If the condition does not improve,
ventilate your home to remove the moisture.
HE365B
Your Enviracaire Elite™ HE365B Humidifier is controlled
by the Honeywell H1008 Automatic Humidity Control
with HumidCalc+™. The automatic humidity control is
mounted in the return air duct where it can be exposed
to the air stream of the return air.
At Outside
Temperature
Recommended
Control Setting
At Outside
Temperature
Recommended
Control Setting
-20°F (-29°C) 15 +10°F (-12°C) 30
-10°F (-23°C) 20 +20°F (-7°C) 35
0°F (-18°C) 25 Above 20°F (-7°C) 40
Humidity Control