Honeywell HE360A Humidifier User Manual


 
HE360A,B POWERED FLOW-THROUGH HUMIDIFIER
11 69-1176—04
NOTE: To prevent leaking, use plastic (Delrin) sleeve rings with plastic tubing. Use
copper sleeve rings only with copper tubing.
d. Insert the tubing into the solenoid valve fitting and support the valve while
tightening the compression nut.
NOTE: Do not over-tighten the compression nut. Moderate tightness prevents
leaking.
e. Repeat steps a. through d. for solenoid valve fitting.
f. Secure tubing with clamps provided.
Fig. 6. Installing feed tubing.
4. Connect a 1/2 in. (13 mm) drain tube to the humidifier drain fitting and run to the
floor drain (see Fig. 7).
a. Slide the drain clamp over the tubing.
b. Push the tubing over the drain nipple on the humidifier.
c. Hand-tighten the clamp around the tubing to secure the humidifier drain.
d. Fasten the drain tubing (can use duct tape) along the route to prevent move-
ment and ensure downward slope for correct drainage.
NOTE: Cut tubing to correct length so the tubing terminates at the drain.
M20176
BRASS COMPRESSION NUT
PLASTIC
COMPRESSION RING
BRASS INSERT
69-1176_A.fm Page 11 Monday, December 7, 2009 9:11 AM