7. Disconnect the drain hose from the drain fitting on the bottom of the humidifier
housing.
8. Clean the drain fitting, if necessary.
9. Bend the drain hose to loosen any mineral deposits.
10. Flush the drain hose with pressurized water (a running tap) to clean the hose.
11. Reattach the drain hose to the drain fitting.
12. Snap the water nozzle back on the tray.
13. Be sure the marked end of the pad is facing up. Place the tray on the new pad.
14. Place the humidifier pad assembly in the humidifier housing. Be sure the water
feed tube is placed in the guide slots.
15. Replace the humidifier cover.
16. Verify the humidifier operation by following the steps in the Checking Your
Humidifier Operation section.
End of Humidification Season
The humidifier needs to be cleaned and shut off at the end of the heating season. Use
the Every 1 to 3 Months section, steps 1 through 15, to shut down for the season.
IMPORTANT
Be sure the humidifier power is off.
Vacation
The humidifier water supply and your humidity control should be turned off. Turn on the
humidifier water supply and reset your humidity control when you return.
M2081
1
COVER
ASSEMBLY
H
UMIDIFIER
P
AD ASSEMBLY
FEED TUBE NOZZLE
W
ATER
D
ISTRIBUTION TRAY
HUMIDIFIE
R
HOUSING
T
HUMB
S
CREW